首页> 外文OA文献 >Variability in P-Glycoprotein Inhibitory Potency (IC50) Using Various in Vitro Experimental Systems: Implications for Universal Digoxin Drug- Drug Interaction Risk Assessment Decision Criterias
【2h】

Variability in P-Glycoprotein Inhibitory Potency (IC50) Using Various in Vitro Experimental Systems: Implications for Universal Digoxin Drug- Drug Interaction Risk Assessment Decision Criterias

机译:p-Glycoprotein抑制效力的变异性(IC50)使用各种体外实验系统:对通用地高辛药物 - 药物相互作用的影响风险评估决策标准

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

A P-glycoprotein (P-gp) IC50 working group was established with 23 participating pharmaceutical and contract research laboratories and one academic institution to assess interlaboratory variability in P-gp IC 50 determinations. Each laboratory followed its in-house protocol to determine in vitro IC50 values for 16 inhibitors using four different test systems: human colon adenocarcinoma cells (Caco-2; eleven laboratories), Madin-Darby canine kidney cells transfected with MDR1 cDNA (MDCKII-MDR1; six laboratories), and Lilly Laboratories Cells-Porcine Kidney Nr. 1 cells transfected with MDR1 cDNA (LLCPK1- MDR1; four laboratories), and membrane vesicles containing human P-glycoprotein (P-gp; five laboratories). For cell models, various equations to calculate remaining transport activity (e.g., efflux ratio, unidirectional flux, net-secretory-flux) were also evaluated. The difference in IC50 values for each of the inhibitors across all test systems and equations ranged from a minimum of 20- and 24-fold between lowest and highest IC50 values for sertraline and isradipine, to a maximum of 407- and 796-fold for telmisartan and verapamil, respectively. For telmisartan and verapamil, variability was greatly influenced by data from one laboratory in each case. Excluding these two data sets brings the range in IC50 values for telmisartan and verapamil down to 69- and 159-fold. The efflux ratiobased equation generally resulted in severalfold lower IC 50 values compared with unidirectional or net-secretory-flux equations. Statistical analysis indicated that variability in IC50 values was mainly due to interlaboratory variability, rather than an implicit systematic difference between test systems. Potential reasons for variability are discussed and the simplest, most robust experimental design for P-gp IC 50 determination proposed. The impact of these findings on drug-drug interaction risk assessment is discussed in the companion article (Ellens et al., 2013) and recommendations are provided. © 2013 by The American Society for Pharmacology.
机译:一个P-糖蛋白(P-gp)IC50工作组与23个参与的制药和合同研究实验室以及一个学术机构共同建立,以评估P-gp IC 50测定中的实验室间变异性。每个实验室都使用四个不同的测试系统按照其内部协议确定16种抑制剂的体外IC50值:人结肠腺癌细胞(Caco-2; 11个实验室),用MDR1 cDNA(MDCKII-MDR1)转染的Madin-Darby犬肾细胞;六个实验室)和礼来实验室Cells-Porcine Kidney Nr。 1个细胞用MDR1 cDNA转染(LLCPK1- MDR1;四个实验室),以及含有人P糖蛋白的膜囊泡(P-gp;五个实验室)。对于细胞模型,还评估了用于计算剩余转运活性的各种方程式(例如,外排比,单向通量,净分泌通量)。在所有测试系统和方程中,每种抑制剂的IC50值之间的差异范围为:舍曲林和伊拉地平的最低和最高IC50值之间的最小20倍和24倍之间,替米沙坦的最大值为407和796倍之间和维拉帕米分别。对于替米沙坦和维拉帕米,每种情况下来自一个实验室的数据极大地影响了变异性。排除这两个数据集,替米沙坦和维拉帕米的IC50值范围降低到69倍和159倍。与单向或净分泌通量方程相比,基于外流比率的方程通常会导致IC 50值降低几倍。统计分析表明,IC50值的变化主要是由于实验室间的变化,而不是测试系统之间存在隐式的系统差异。讨论了可变性的潜在原因,并提出了用于P-gp IC 50测定的最简单,最可靠的实验设计。这些发现对药物-药物相互作用风险评估的影响在随附的文章中进行了讨论(Ellens等,2013),并提供了建议。 ©2013,美国药理学会。

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号