Objective: To evaluate the accuracy and sensitivity of a fully automatic shape model matching (FASMM) system to derive statistical shape models (SSMs) of the proximal femur from non-standardised anteroposterior (AP) pelvic radiographs. Design: AP pelvic radiographs obtained with informed consent and appropriate ethical approval were available for 1105 subjects with unilateral hip osteoarthritis (OA) who had been recruited previously for The arcOGEN Study. The FASMM system was applied to capture the shape of the unaffected (i.e., without signs of radiographic OA) proximal femur from these radiographs. The accuracy and sensitivity of the FASMM system in calculating geometric measurements of the proximal femur and in shape representation were evaluated relative to validated manual methods. Results: De novo application of the FASMM system had a mean point-to-curve error of less than 0.9mm in 99% of images (n=266). Geometric measurements generated by the FASMM system were as accurate as those obtained manually. The analysis of the SSMs generated by the FASMM system for male and female subject groups identified more significant differences (in five of 17 SSM modes after Bonferroni adjustment) in their global proximal femur shape than those obtained from the analysis of conventional geometric measurements. Multivariate gender-classification accuracy was higher when using SSM mode values (76.3%) than when using conventional hip geometric measurements (71.8%). Conclusions: The FASMM system rapidly and accurately generates a global SSM of the proximal femur from radiographs of varying quality and resolution. This system will facilitate complex morphometric analysis of global shape variation across large datasets. The FASMM system could be adapted to generate SSMs from the radiographs of other skeletal structures such as the hand, knee or pelvis. © 2013 Osteoarthritis Research Society International.
机译:目的:评估全自动形状模型匹配(FASMM)系统从非标准化前后位(AP)骨盆X线照片得出股骨近端统计形状模型(SSM)的准确性和敏感性。设计:事先招募用于ArcOGEN研究的1105名单侧髋骨关节炎(OA)受试者可获得经知情同意并获得适当的伦理批准的AP骨盆摄影。应用FASMM系统从这些X线照片中捕获未受影响的股骨(即没有X线照相OA的迹象)的形状。相对于已验证的手动方法,评估了FASMM系统在计算股骨近端的几何尺寸和形状表示中的准确性和敏感性。结果:在99%的图像中,从头开始使用FASMM系统的平均点到曲线误差小于0.9毫米(n = 266)。 FASMM系统生成的几何测量结果与手动获得的结果一样准确。由FASMM系统针对男性和女性受试者组生成的SSM的分析发现,其股骨近端总体形状(从Bonferroni调整后的17种SSM模式中有5种)比传统几何测量方法获得的差异更大。使用SSM模式值时,多变量性别分类准确性更高(76.3%),而使用常规髋部几何测量值则更高(71.8%)。结论:FASMM系统可以根据不同质量和分辨率的X线照片快速,准确地生成股骨近端的整体SSM。该系统将有助于跨大型数据集对全局形状变化进行复杂的形态分析。 FASMM系统可以适用于从其他骨骼结构(如手,膝盖或骨盆)的X光片生成SSM。 ©2013国际骨关节炎研究学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号