A Novel On-Eye Wettability Analyzer for Soft Contact Lenses

机译:一种用于软性隐形眼镜的新型眼睛润湿性分析仪

摘要

Purpose.: To develop novel methodology to assess two in vivo wettability parameters, contact angle and index of liquid spreading (ILS), for hydrogel contact lenses and to provide a comprehensive investigation of the measurement errors (repeatability) associated with these two parameters. Methods.: A Novel On-eye Wettability Analyzer (NOWA) was constructed which delivered a drop of 0.4% sodium hyaluronate mixed with sodium fluorescein directly on to a lens surface in vivo while a two-camera digital system recorded both the resultant contact angle and liquid spreading. Ten subjects each wore a different etafilcon A lens (-0.50 DS) in the right eye for 30 min before measurement on three separate occasions. For contact angles, the coefficient of repeatability (COR) associated with three measurement conditions (image analysis COR, intrasubject COR, and intersubject COR) was determined. For ILS, the COR associated with two measurement conditions (intrasubject COR and intersubject COR) was also determined. Results.: The in vivo contact angle for the etafilcon A lens was 19.8° ± 2.9° (mean ± standard deviation). COR values for contact angle were 3.2°, 5.2°, and 8.0° for image analysis, intrasubject measures, and intersubject measures, respectively. The mean ± standard deviation ILS was 2.0 ± 0.3 mm, and COR values were 0.4 and 0.8 mm for intrasubject and intersubject measures, respectively. Conclusions.: This research demonstrates that it is possible to obtain hydrogel lens contact angles in vivo and to provide a new wettability parameter (ILS) with the NOWA instrumentation. The COR values obtained were considered to be acceptable. Intersubject COR values were greater than intrasubject COR values for both contact angle and ILS; this is likely to be due to greater variability of tear film characteristics between subjects than within an individual. The use of this novel methodology and its associated clinical parameters across a wider range of lens types in various clinical situations warrants further investigation. Copyright © 2011 American Academy of Optometry.
机译:目的:开发新颖的方法来评估水凝胶隐形眼镜的两个体内润湿性参数(接触角和液体散布指数(ILS)),并对与这两个参数相关的测量误差(重复性)进行全面研究。方法:构造了一种新型的眼上湿润分析仪(NOWA),该混合物在体内将一滴0.4%的透明质酸钠与荧光素钠的混合物直接滴到了晶状体表面上,而双摄像头数字系统记录了所得的接触角和液体扩散。十名受试者分别在右眼上佩戴不同的etafilcon A晶状体(-0.50 DS)30分钟,然后在三个不同的场合进行测量。对于接触角,确定了与三个测量条件(图像分析COR,受试者体内COR和受试者间COR)相关的重复性系数(COR)。对于ILS,还确定了与两个测量条件(对象内COR和对象间COR)相关的COR。结果:etafilcon A晶状体的体内接触角为19.8°±2.9°(均值±标准差)。对于图像分析,对象内测量和对象间测量,接触角的COR值分别为3.2°,5.2°和8.0°。受试者内和受试者间测量的平均值±标准偏差ILS为2.0±0.3 mm,COR值分别为0.4和0.8 mm。结论:这项研究表明,使用NOWA仪器可以在体内获得水凝胶镜片的接触角并提供新的润湿性参数(ILS)。获得的COR值被认为是可接受的。对于接触角和ILS,受试者间COR值均大于受试者内COR值;这很可能是由于受试者之间的泪膜特性差异比个人差异更大。在各种临床情况下,这种新颖的方法及其在更大范围的镜片类型上的相关临床参数的使用值得进一步研究。版权所有©2011美国验光学院。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号