Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR line: An international study

机译:基于凝血酶原时间/ INR线的国际标准化比率(INR)推导的简化方法:一项国际研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: The need to perform local International Sensitivity Index (ISI) calibrations and in particular the requirement for amanual method for prothrombin time (PT) determination, have proved to be obstacles to application of the WHO scheme for PT standardization. METHODS: We used international normalized ratio (INR) derived with a set of only 5 European Concerted Action on Anticoagulation (ECAA) lyophilized calibrant plasmas, certified manually by expert centers with reference thromboplastins, to determine a local PT/INR Line. We compared results of an independent set of validation plasmas with INRs from conventional ISI calibrations and with manually certified INRs. RESULTS: The mean certified INR of 5 lyophilized validation plasmas was 2.41 with human thromboplastin, 2.04 with bovine/combined, and 2.80 with rabbit. With 42 human reagents, the mean observed INR of the validation plasmas was 2.68 (11.2% deviation from certified INR). Deviation was reduced to 0.4% with both local ISI calibration and the PT/INR Line. Eight results based on bovine/combined thromboplastin gave an INR deviation of 4.9%, becoming 0.5% after ISI calibration and 2.4% with the PT/INR Line. Six results with rabbit reagents deviated from certified INR by 2.5%. After ISI calibration, deviation became 1.1%, and with the PT/INR Line, 0.7%. The PT/INR Line gave similar results with both linear and orthogonal regression analysis. The total proportion of validation plasmas giving INR within 10% deviation from certified values was 42.5% with uncorrected INR, which increased to 92.1% with local ISI calibration and 93.2% with the PT/INR Line. CONCLUSIONS: The PT/INR Line procedure with 5 ECAA calibrant plasmas successfully substitutes for local ISI calibrations in deriving reliable INRs. © 2010 American Association for Clinical Chemistry.
机译:背景:执行本地国际敏感性指数(ISI)校准的需求,尤其是对手工测定凝血酶原时间(PT)的方法的要求,已被证明阻碍了WHO PT标准化计划的应用。方法:我们使用国际标准化比率(INR),该比率是通过仅由5种欧洲抗凝协调行动(ECAA)冻干校准物血浆获得的,并由专家中心通过参考凝血活酶原手动认证,以确定当地的PT / INR线。我们将独立的一组验证血浆的结果与常规ISI校准的INR和手动认证的INR进行了比较。结果:5种冻干验证血浆的平均认证INR为:人凝血活酶为2.41,牛/联合血浆为2.04,兔为2.80。使用42种人类试剂,验证血浆的平均INR观察值为2.68(与认证INR的偏差为11.2%)。使用本地ISI校准和PT / INR线时,偏差均降低到0.4%。基于牛/组合凝血活酶的八项结果得出INR偏差为4.9%,在ISI校准后为0.5%,在PT / INR系中为2.4%。兔试剂的六项结果与认证的INR偏离2.5%。经过ISI校准后,偏差变为1.1%,而PT / INR线为0.7%。 PT / INR线在线性和正交回归分析中给出了相似的结果。在未校正INR的情况下,给出INR与认证值相差10%以内的验证血浆的总比例为42.5%,使用本地ISI校准时,其上升至92.1%,而使用PT / INR线时,上升至93.2%。结论:采用5种ECAA校准血浆的PT / INR线程序成功替代了本地ISI校准,从而获得可靠的INR。 ©2010美国临床化学协会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号