Effects and Analysis of Minimum Pulse Width Limitation on Adaptive DC Voltage Control of Grid Converters

机译:最小脉冲宽度限制对并网逆变器自适应直流电压控制的影响及分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper presents an adaptive dc-link voltage controller for the purpose of decreasing the operating dc-link voltage in a back-to-back converter system. An outer loop tocontrol the maximum modulation (Mmax) index is added to the conventional dc-link voltage controller, and hence the system can online adapt its dc-link voltage reference based on the system operating state. Furthermore, the relationship between current THD, minimum pulse width limitation and Mmax index reference is analyzed in order to obtain an optimized performance of the system. Finally, the dynamic performance and analysis of controller is investigated by experimental results.
机译:本文提出了一种自适应直流链路电压控制器,目的是降低背靠背转换器系统中的工作直流链路电压。在传统的直流链路电压控制器中增加了一个用于控制最大调制(Mmax)指标的外部环路,因此系统可以根据系统工作状态在线调整其直流链路参考电压。此外,分析了当前THD,最小脉冲宽度限制和Mmax指标参考之间的关系,以获得系统的优化性能。最后,通过实验结果研究了控制器的动态性能和分析。