摘要

The Y-source topology has a unique advantage of having high voltages gain with small shoot through duty cycles. Furthermore, having the advantage of high modulation index increases the power density and improves the performance of the converter. In this paper, a collective thermal and efficiency investigation is performed in order to improve the reliability of the converter. Losses evaluation in the semiconductor devices (switching/conduction), the capacitors (ESR), and the inductors (core/winding) are presented. Moreover, the junction temperature evaluation of the devices is considered under 25◦ C ambient temperature. The analysis is carried out at the following voltages gain (2, 3, and 4), and at the following winding factors (4, and 5) using PLECS toolbox. The results show that, the power losses and the junction temperature are directly proportional with the voltage gain and the winding factor.
机译:Y源拓扑具有一个独特的优势,即它具有高电压增益和较小的贯穿占空比。此外,具有高调制指数的优点增加了功率密度并改善了转换器的性能。在本文中,进行了集体的热效率研究,以提高转换器的可靠性。介绍了半导体器件(开关/传导),电容器(ESR)和电感器(铁芯/绕组)中的损耗评估。此外,器件的结温评估是在25°C环境温度下进行的。使用PLECS工具箱,在以下电压增益(2、3和4)和以下绕组系数(4和5)下进行分析。结果表明,功率损耗和结温与电压增益和绕组系数成正比。