Air tightness measurements in older Danish single-family houses

机译:丹麦老式单户住宅的气密性测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper reports and discusses the air tightness of the building envelope in existing single-family houses in Denmark. The air tightness of the building envelope depends in particular on the performance of specific construction details. There is a lack of knowledge about the air tightness of the building envelope of older buildings despite the fact that the air tightness has a major influence on the energy use. In connection with renovation of the Danish building stock, the coming years will see increased focus on the air tightness of the building envelope like in other countries. This paper presents the results of measurements in 16 single-family houses built between 1880 and 2007. The air tightness of the building envelope was measured according to EN ISO 9972 using the blower-door technique. The results are compared with measurement results of the average air-change rate in the same houses measured over a period of 1-3 weeks when the houses were in normal use. The measurement results of the air tightness of the building envelope range from 1.1 to 5.8 l/(s·m²) at 50 Pa. The investigated houses are all naturally ventilated. The results of the ventilation measurements showed an outdoor air supply ranging from 0.09 to 0.28 l/(s·m²) per heated floor area, which is below the requirement stipulated in the Danish Building Regulations of 0.3 l/(s·m²).Typically, leaks are observed in connection with penetrations of the envelope, e.g. for electrical installations, exhaust ducts and chimneys. In addition, leaks are observed around older windows and doors and in connection with wooden ceilings and attic hatches. The findings should be taken into account when renovating older single-family houses.
机译:本文报告并讨论了丹麦现有单户住宅中建筑围护结构的气密性。建筑围护结构的气密性尤其取决于特定建筑细节的性能。尽管事实上气密性对能源的使用有很大影响,但对较老建筑的建筑围护结构的气密性缺乏了解。与丹麦建筑材料的翻新相关,未来几年将像其他国家一样,越来越关注建筑围护结构的气密性。本文介绍了在1880年至2007年之间建造的16栋单户住宅中的测量结果。根据EN ISO 9972使用鼓风门技术测量了建筑物围护结构的气密性。将结果与在正常使用情况下在1-3周内测量的相同房屋的平均换气率的测量结果进行比较。在50 Pa时,建筑物围护结构的气密性测量结果为1.1到5.8 l /(s·m²)。被调查的房屋全部是自然通风的。通风测量结果显示,室外空气供应量/加热地板面积为0.09至0.28 l /(s·m²),低于丹麦建筑法规规定的0.3 l /(s·m²)的要求。 ,观察到与信封穿透有关的泄漏,例如用于电气装置,排气管和烟囱。此外,在较旧的门窗周围以及木制天花板和阁楼舱口中都发现了泄漏。在翻新旧的单户住宅时,应考虑到这一发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号