首页> 外文OA文献 >Air-Water Cooling System for Switch-Mode Power Supplies
【2h】

Air-Water Cooling System for Switch-Mode Power Supplies

机译:用于开关电源的空气 - 水冷却系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated; the trends of efficiency and power dissipation are evidenced.
机译:这些结果是对电视数字功率放大器的开关电源(SMPS)的气液冷却系统中的热传递进行实验研究的结果。由于这些SMPS具有高功率和高紧凑性的特点,从而使得标准冷却技术难以使用,因此开发了一种新的冷却系统,该系统使用水和空气作为冷却介质。有源元件(MOSFET)用液体冷板冷却,无源元件(冷凝器,变压器,线圈)用空气流冷却,然后用冷板冷却。通过将冷却系统插入可以控制冷却水的实验工具中,可以测量SMPS重要点的温度。还测量电效率。评估此冷却系统的热性能对限制其最高运行温度很有用。证明了冷却系统的功效;效率和功耗的趋势得到了证明。

著录项

  • 作者

    Casano, G.; Piva, S.;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号