首页> 外文OA文献 >Diagnostic accuracy of 3D color volume-rendered CT images for peroneal tendon dislocation in patients with acute calcaneal fractures
【2h】

Diagnostic accuracy of 3D color volume-rendered CT images for peroneal tendon dislocation in patients with acute calcaneal fractures

机译:三维彩色体积CT图像对急性跟骨骨折患者腓骨肌腱脱位的诊断准确性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Use of three-dimensional (3D) color volume-rendered (VR) images has been reported to be more time-efficient compared to that of cross-sectional computed tomography (CT) images for the diagnosis of peroneal tendon dislocation. However, the diagnostic performance of this technique has not been studied. Purpose: To test diagnostic accuracy of 3D color VR CT images of ankle for peroneal tendon dislocation in patients with acute calcaneal fractures. Material and Methods: The study consisted of 121 ankle CT studies from 105 consecutive patients (85 men, 20 women; mean age, 42 years; age range, 16-75 years) with acute calcaneal fractures. Peroneal tendon dislocation was diagnosed on multiplanar CT images by consensus of two experienced musculoskeletal radiologists, which served as the reference standard. Three other musculoskeletal radiologists independently reviewed 3D images alone on a work-station. The readers determined whether or not there was peroneal tendon dislocation using three degrees of certainty (definite, probable, and possible). Diagnostic performance of 3D images for peroneal tendon dislocation was evaluated by calculating the sensitivities, specificities, and area under the receiver-operating characteristic (ROC) curves. Results: Forty-eight (40%) out of 121 studies showed peroneal tendon dislocation based on the expert readings using multiplanar reformatted images. Sensitivities/specificities of 3D images measured 0.92/0.81, 0.88/0.90, and 0.81/0.92 for three readers, respectively. The area under the proper binormal ROC curve based on all three readers (0.93, 0.94, and 0.92) measured 0.93 with a 95% confidence interval of 0.89-0.98. Conclusion: Diagnostic accuracy of 3D images is comparable to, but not as good as that of MPR images for the diagnosis of peroneal tendon dislocation in patients with acute calcaneal fractures.
机译:背景:据报道,与横截面计算机断层扫描(CT)图像相比,使用三维(3D)彩色体积渲染(VR)图像诊断腓骨肌腱脱位更省时。但是,尚未研究该技术的诊断性能。目的:测试踝关节的3D彩色VR CT图像对急性跟骨骨折患者腓骨腱脱位的诊断准确性。资料和方法:该研究包括121例踝关节CT研究,来自105例连续的急性跟骨骨折患者(85例男性,20例女性;平均年龄42岁;年龄范围16-75岁)。经两位经验丰富的骨骼肌肉放射科医生的共识,在多平面CT图像上诊断出腓骨腱脱位,并以此作为参考标准。其他三位骨骼肌肉放射科医生单独在工作站上单独查看了3D图像。读者使用三个确定性程度(确定的,可能的和可能的)来确定是否存在腓骨腱脱位。通过计算敏感性,特异性和受体工作特性(ROC)曲线下的面积,评估3D图像对腓骨腱脱位的诊断性能。结果:在121项研究中,有48项(40%)显示了腓骨腱脱位,这是基于专家读数并使用多平面重排格式的图像得出的。 3个图像的3D图像的灵敏度/特异度分别为0.92 / 0.81、0.88 / 0.90和0.81 / 0.92。基于所有三个读取器(0.93、0.94和0.92)的适当双正态ROC曲线下的面积测得的值为0.93,95%置信区间为0.89-0.98。结论:3D图像在急性跟骨骨折患者中腓骨腱脱位的诊断准确性与MPR图像相当,但不如MPR图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号