首页> 外文OA文献 >Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening.
【2h】

Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening.

机译:用于青光眼筛查的时域和光谱域光学相干断层扫描的性能。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: To investigate the measures of validity for selective or population screening of the time-domain Stratus and the spectral-domain Cirrus Optical Coherence Tomography (OCT) imaging techniques in a population-based sample and in clinical glaucoma patients at different stages of glaucoma. Patients and methods: A random sample of 307 subjects living in two rural areas in southern Sweden, and a random sample of 394 clinical glaucoma patients were selected. A large battery of examinations, including Stratus and Cirrus OCT was performed. OCT retinal nerve fibre layer (RNFL) thickness analyses for average thickness, quadrant and clock-hour sectors were compared with normative significance limits available in the instruments. Results: The population-based sample included 129 healthy and nine glaucoma subjects, and the sample of clinical glaucoma patients included 138 patients. Specificity and positive predictive values were generally better with Stratus than for Cirrus, and sensitivity was generally better with Cirrus. With the average RNFL thickness parameter, Stratus reached 100% specificity and a positive predictive value of 100% and 68% sensitivity in the whole group of the clinical glaucoma patients, but sensitivity was only 28% among the earliest stage glaucoma patients. Sensitivity increased considerably when relying on the quadrant sector parameter, while specificity decreased only marginally. Conclusion: Stratus, with high specificity and positive predictive values, seemed to be best of choice for screening purposes, while Cirrus, with high sensitivity, was the better choice for early detection.
机译:目的:研究针对以人群为基础的样本和处于青光眼不同阶段的临床青光眼患者的时域层云和光谱域卷云光学相干断层扫描(OCT)成像技术的选择性或总体筛查的有效性的措施。患者和方法:随机抽取瑞典南部两个农村地区的307名受试者作为样本,并随机选择394名临床青光眼患者。进行了包括Stratus和Cirrus OCT在内的大量检查。将OCT视网膜神经纤维层(RNFL)厚度分析的平均厚度,象限和时钟时间段与仪器中可用的规范性显着性限值进行了比较。结果:基于人群的样本包括129名健康和9名青光眼受试者,临床青光眼患者的样本包括138名患者。 Stratus的特异性和阳性预测值通常比Cirrus更好,而Cirrus的敏感性通常更好。使用平均RNFL厚度参数,在整个临床青光眼患者组中,Stratus达到100%的特异性和100%和68%敏感性的阳性预测值,但是在早期青光眼患者中敏感性仅为28%。依靠象限扇形参数时,灵敏度显着提高,而特异性仅略有下降。结论:具有高特异性和阳性预测值的地层似乎是筛选目的的最佳选择,而具有高灵敏度的Cirrus是早期检测的更好选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号