首页> 外文OA文献 >Retrofitting Conventional Electric Domestic Hot Water Heaters to Solar Water Heating Systems in Single-Family Houses-Model Validation and Optimization
【2h】

Retrofitting Conventional Electric Domestic Hot Water Heaters to Solar Water Heating Systems in Single-Family Houses-Model Validation and Optimization

机译:将常规电热水加热器改造为单户住宅太阳能热水系统 - 模型验证和优化

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

System cost reductions and development of standardised plug-and-function systems are some of the most important goals for solar heating technology development. Retrofitting hot water boilers in single-family houses when installing solar collectors has the potential to significantly reduce both material and installation costs. In this study, the TRNSYS simulation models of the retrofitting solar thermal system were validated against measurements. Results show that the validated models are in good agreement with measurements. On an annual basis a deviation of 2.5% out of 1099 kWh was obtained between the auxiliary energy from results and from the simulation model for a complete system. Using the validated model a system optimization was carried out with respect to control strategies for auxiliary heating, heat losses and volume of auxiliary storage. A sensitivity analysis was carried out regarding different volumes of retrofitted hot water boiler, DHW profiles and climates. It was estimated that, with adequate improvements, extended annual solar fractions of 60%, 78% and 81% can be achieved for Lund (Sweden), Lisbon (Portugal) and Lusaka (Zambia), respectively. The correspondent collector area was 6, 4 and 3 m(2), respectively. The studied retrofitted system achieves a comparable performance with conventional solar thermal systems with the potential to reduce the investment cost.
机译:降低系统成本和开发标准化的即插即用系统是太阳能供热技术发展的一些最重要目标。在安装太阳能收集器时,在单户住宅中改装热水锅炉有可能显着降低材料和安装成本。在这项研究中,针对测量结果验证了改造后的太阳能热系统的TRNSYS仿真模型。结果表明,经过验证的模型与测量结果吻合良好。每年从结果中得出的辅助能量与整个系统的仿真模型之间的偏差为1099 kWh,偏差为2.5%。使用经过验证的模型,对辅助加热,热量损失和辅助存储量的控制策略进行了系统优化。对改装后的热水锅炉的不同容积,DHW曲线和气候进行了敏感性分析。据估计,如果进行适当的改进,隆德(瑞典),里斯本(葡萄牙)和卢萨卡(赞比亚)的年太阳辐射率可分别达到60%,78%和81%。对应的收集器面积分别为6、4和3 m(2)。所研究的改装系统可实现与常规太阳能热系统相当的性能,并有可能降低投资成本。

著录项

  • 作者

    Bernardo, Ricardo;

  • 作者单位
  • 年度 2013
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号