首页> 外文OA文献 >Evaluation of aerodynamic particle sizer and electrical low-pressure impactor for unimodal and bimodal mass-weighted size distributions
【2h】

Evaluation of aerodynamic particle sizer and electrical low-pressure impactor for unimodal and bimodal mass-weighted size distributions

机译:用于单峰和双峰质量加权尺寸分布的空气动力学粒度分析仪和电动低压冲击器的评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this study was to investigate the feasibility of the Aerodynamic Particle Sizer (APS) and the Electrical Low-Pressure Impactor (ELPI) to study mass weighted particle size distributions. Unimodal and bimodal liquid test aerosols were produced to a small chamber. Simultaneous measurements were performed with an APS 3320, an APS 3321, an ELPI and a Dekati Low-Pressure Impactor (DLPI) analyzed gravimetrically. ELPI current and mass responses were simulated for lognormal size distributions using a parameterization of the impactor kernel functions. In experiments with a single coarse mode, the mass ratio to the DLPI was between 0.75 and 1.15 for both APS models up to 5 mu m and for the ELPI up to 3 mu m. For larger sizes the ELPI and APS 3320 overestimated and the APS 3321 underestimated the concentration. In experiments with a single fine mode, submicrometer ELPI and DLPI results were in good agreement. However, in contrast to the DLPI all three spectrometers showed a significant mass fraction above 1 mu m. In experiments with a bimodal size distribution, the mass ratios were altered compared to single coarse mode experiments. Simulations showed that uncertainties in ELPI measurements of larger particles occur when concentrations of small particles are high. Several mechanisms that may bias ELPI and APS measurements are described. With knowledge of these, ELPI and APS 3321 can, under many circumstances give accurate time-resolved mass size distributions for particles smaller than 3 and 5 mu m, respectively.
机译:这项研究的目的是研究空气动力学粒度仪(APS)和低压电气冲击器(ELPI)研究质量加权粒度分布的可行性。将单峰和双峰液体测试气雾剂生产到一个小室中。用重量分析的APS 3320,APS 3321,ELPI和Dekati低压冲击器(DLPI)进行了同时测量。使用冲击器内核函数的参数化,模拟了ELPI电流和质量响应的对数正态尺寸分布。在单一粗略模式下的实验中,两种APS模型(最大5微米)和ELPI高达3微米(相对于DLPI的质量比)都在0.75和1.15之间。对于较大的尺寸,ELPI和APS 3320高估了,而APS 3321低估了浓度。在单精细模式下的实验中,亚微米ELPI和DLPI结果非常吻合。但是,与DLPI相比,所有三个光谱仪均显示出1微米以上的明显质量分数。在具有双峰尺寸分布的实验中,与单次粗模式实验相比,质量比发生了变化。模拟表明,当小颗粒浓度较高时,较大颗粒的ELPI测量不确定。描述了可能会使ELPI和APS测量产生偏差的几种机制。有了这些知识,ELPI和APS 3321在许多情况下可以分别对小于3和5微米的颗粒给出精确的时间分辨质量尺寸分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号