Quantifying the absorption and reduced scattering coefficients of tissuelike turbid media over a broad spectral range with noncontact Fourier-transform hyperspectral imaging

机译:利用非接触傅里叶变换高光谱成像量化宽光谱范围内的组织混浊介质的吸收和降低的散射系数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Absorption (mu (a)) and reduced scattering (mu (s)') spectra of turbid media were quanti fied with a noncontact imaging approach based on a Fourier-transform interferometric imaging system (FTIIS). The FTIIS was used to collect hyperspectral images of the steady-state diffuse reflectance from turbid media. Spatially resolved reflectance data from Monte Carlo simulations were fitted to the recorded hyperspectral images to quantify mu (a) and mu (s)' spectra in the 550-850-nm region. A simple and effective calibration approach was introduced to account for the instrument response. With reflectance data that were close to and far from the source (0.5-6.5 mm), mu (a) and mu (')(s) of homogeneous, semi-infinite turbid phantoms with optical property ranges comparable with those of tissues were determined with an accuracy of +/-7% and +/-3%, respectively. Prediction accuracy for mu (a) and mu (s)' degraded to +/-12% and +/-4%, respectively, when only reflectance data close to the source (0.5-2.5 mm) were used. Results indicate that reflectance data close to and far hom the source are necessary for optimal quantification of mu (a) and mu (s)'. The spectral properties of mu (a) and mu (s)' values were used to determine the concentrations of absorbers and scatterers, respectively. Absorber and scatterer concentrations of two-chromophore turbid media were determined with an accuracy of +/-5% and +/-3%, respectively. (C) 2000 Optical Society of America OCIS codes: 170.0110, 170.7050, 170.6510, 070.2590, 120.3180.
机译:使用基于傅立叶变换干涉成像系统(FTIIS)的非接触成像方法对浑浊介质的吸收(mu(a))和减少的散射(mu(s)')光谱进行定量。 FTIIS用于收集来自混浊介质的稳态漫反射率的高光谱图像。将来自蒙特卡洛模拟的空间分辨反射率数据拟合到记录的高光谱图像上,以量化550-850 nm区域的mu(a)和mu(s)'光谱。引入了一种简单有效的校准方法来说明仪器的响应。利用接近和远离光源(0.5-6.5 mm)的反射率数据,确定光学特性范围与组织相当的均质,半无限浑浊体模的mu(a)和mu(')(s)。精度分别为+/- 7%和+/- 3%。当仅使用接近光源(0.5-2.5 mm)的反射率数据时,mu(a)和mu(s)'的预测精度分别降低到+/- 12%和+/- 4%。结果表明,接近和远离光源的反射率数据对于mu(a)和mu(s)'的最佳量化是必要的。 mu(a)和mu(s)'值的光谱特性分别用于确定吸收剂和散射剂的浓度。确定了两种生色团混浊介质的吸收剂和散射剂浓度,其准确度分别为+/- 5%和+/- 3%。 (C)2000美国光学学会OCIS编码:170.0110、170.7050、170.6510、070.2590、120.3180。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号