BACKGROUND : A chemistry point-of-care analyzer would be useful for evaluating injured wildlife, particularly white rhinoceros (Ceratotherium simum) that survive poaching attempts. The IDEXX VetTest® could be suitable, but species-specific validation, development of a statistical quality control (QC) strategy and evaluation under field conditions is necessary. OBJECTIVES : The objectives were to 1) validate the VetTest for the white rhinoceros, 2) perform QC validation on the VetTest and generate a statistical QC strategy and 3) apply this QC strategy to monitor performance under typical field conditions. METHODS : Differences between white rhinoceros heparin plasma and serum, short-term imprecision and reportable range using rhinoceros plasma and long-term imprecision usingcommercial quality control material (QCM) was assessed against prescribed total allowable error (TEa) for up to 15 analytes. QC validation was performed using data from the long-term imprecision study and TEa. A QC strategy using QCM was developed and used to monitor performance under field conditions. RESULTS : Imprecision was acceptable for all analytes except for ALP, ALT and AST at lowactivities. The reportable range for AST and LDH differed from the manufacturer’sspecifications. Eleven analytes were suitable for statistical QC using the 13s rule, three using the 2s rule; ALP was not suitable. In the field, observed error was less than TEa for all fifteen analytes and the sigma metric was >3.0 for twelve analytes. CONCLUSIONS : The VetTest is suitable for use in the white rhinoceros. Statistical QC is possible for most analytes and useful for evaluation of field performance.
机译:背景:化学即时分析仪可用于评估受伤的野生动物,尤其是白犀牛(Ceratotherium simum),它们可以在偷猎中幸存下来。 IDEXXVetTest®可能合适,但是必须进行特定物种的验证,制定统计质量控制(QC)策略以及在野外条件下进行评估。目的:目标是1)验证白犀牛的VetTest; 2)对VetTest进行QC验证并生成统计质量控制策略; 3)应用此质量控制策略来监测典型田间条件下的性能。方法:根据规定的总允许误差(TEa)评估了多达15种分析物的白犀牛肝素血浆和血清之间的差异,使用犀牛血浆的短期不准确度和可报告范围以及使用商业质量控制材料(QCM)的长期不准确度之间的差异。使用来自长期不精确性研究和TEa的数据进行QC验证。开发了使用QCM的质量控制策略,并将其用于监视现场条件下的性能。结果:除低活性的ALP,ALT和AST外,所有分析物的不精密度均可接受。 AST和LDH的可报告范围与制造商的规范不同。使用13s规则的11种分析物适合进行统计质量控制,使用2s规则的3种适合于统计质量控制。 ALP不适合。在现场,对于所有十五种分析物,观察到的误差均小于TEa,对于十二种分析物,西格玛度量值大于3.0。结论:VetTest适用于白犀牛。统计质量控制对大多数分析物都是可行的,并且对评估现场性能很有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号