首页> 外文OA文献 >Measuring eccentric strength of the shoulder external rotators using a handheld dynamometer : reliability and validity
【2h】

Measuring eccentric strength of the shoulder external rotators using a handheld dynamometer : reliability and validity

机译:使用手持式测力计测量肩部外转子的偏心强度:可靠性和有效性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Context: Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective: To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design: Descriptive laboratory study. Setting: Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants: Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s): The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30 degrees/s over 90 degrees of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s): Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results: The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions: Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD.
机译:背景:肩部力量评估在肩部区域的临床检查中起着重要作用。偏心强度测量在指导临床医生预防伤害或受伤后重返比赛中特别重要。目的:研究标准化的肱骨外旋肌偏心强度测量方案的绝对和相对可靠性和有效性。设计:描述性实验室研究。地点:比利时根特大学康复科学与物理治疗系的测试环境。患者或其他参与者:25名无肩痛病史的健康参与者(9名男性和16名女性)由2名独立评估者使用手持测功机(HHD)进行了测试,并进行了等速测试程序。干预措施:临床规程使用HHD,DynaPort加速度计测量90度运动范围内以30度/ s测试的加速度和角速度,以及Biodex测力计测量等速运动。主要指标:三个偏心强度测量:(1)具有HHD的测试仪1,(2)具有HHD的测试仪2和(3)Biodex等速强度测量。结果:测试人员之间的可靠性极佳(0.879和0.858),而测试人员之间的可靠性良好,测试人员之间的组内相关系数为0.714。在HHD和等速数据之间的Pearson乘积矩相关系数分别为0.78和0.70,表明该新方法的有效性。结论:使用HHD,可以在临床环境中对标准化的偏心肩袖强度进行测试和测量,其信度和效用均达到或优于优秀。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号