首页> 外文OA文献 >Determination of Sr-90 at ultratrace levels in urine by ICP-MS
【2h】

Determination of Sr-90 at ultratrace levels in urine by ICP-MS

机译:ICp-ms法测定尿液中超痕量sr-90的含量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sr-90 appears as a radionuclide in the decay series of nuclear fission and can therefore be found in nuclear waste or released by nuclear accidents. Current methods for the detection of this radionuclide are time consuming and may be prone to a large variety of interferents. In this work, inductively coupled plasma mass spectrometry is explored for the determination of Sr-90 in the presence of stable zirconium in urine. Specific techniques are investigated to remove this as well as other contributions to the background at m/z = 90. A quadrupole ICP-MS equipped with a hexapole collision cell is first explored (final LOD = 2 ng L-1 for water samples), however, the desired limit of detection for Sr-90 in urine is quite low (0.02 pg L-1). The performance of a double-focusing sector field ICP mass spectrometer (ICP-SFMS) is further investigated, which allows measurement of Sr-90 at the ultratrace level. Other potential interferences were investigated and instrumental detection limits are calculated as 3 pg L-1 for water samples. Final parameters include the use of a cool plasma and medium mass resolution in ICP-SFMS. The method is applied to the analysis of Sr-90 extracted from urine using a crown ether extraction resin and concentrated (enrichment factor: 200); high levels of natural strontium in the separated fraction (of about 1 mug mL(-1)) equate to higher detection limits (80 pg L-1) due to Sr-88(+) at m/z = 90 and the relatively low abundance sensitivity of ICP-SFMS at medium mass resolution of 6 x 10(-7). This detection limit in the separated fraction corresponds to the detection limit of 0.4 pg L-1 in the original urine sample. The recovery of Sr-90, determined with the developed analytical method in spiked urine samples, was in the range of 82-86%.
机译:Sr-90在核裂变的衰变序列中以放射性核素的形式出现,因此可以在核废料中发现或由核事故释放。用于检测这种放射性核素的当前方法很耗时,并且可能易于产生多种干扰物。在这项工作中,探索了电感耦合等离子体质谱法在尿液中存在稳定锆的情况下测定Sr-90的方法。已研究了特定技术以消除m / z = 90时对背景的影响以及对背景的其他影响。首先研究了配备六极碰撞池的四极杆ICP-MS(对于水样品,最终LOD = 2 ng L-1),但是,尿液中Sr-90的理想检测限很低(0.02 pg L-1)。进一步研究了双聚焦扇形场ICP质谱仪(ICP-SFMS)的性能,该性能可在超痕量水平下测量Sr-90。研究了其他潜在干扰,对水样品的仪器检出限计算为3 pg L-1。最终参数包括在ICP-SFMS中使用冷等离子体和中等质量分辨率。该方法适用于使用冠醚提取树脂从尿液中提取的Sr-90进行分析并进行浓缩(富集系数:200)。由于m / z = 90时Sr-88(+)的存在,分离出的馏分中的天然锶含量高(约1杯mL(-1))相当于较高的检出限(80 pg L-1),相对较低中等质量分辨率为6 x 10(-7)时ICP-SFMS的丰度灵敏度分离级分中的该检测限对应于原始尿液样品中的0.4 pg L-1的检测限。用发达的分析方法测定的加标尿样中Sr-90的回收率在82-86%的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号