In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systemshave significant geometrical differences, such as the axial fieldof view (110 mm on ClearPET versus 45.6 mm on rPET-1), theconfiguration of the detectors (whole ring on ClearPET versusone pair of planar blocks on rPET-1) and the use of an axialshift between ClearPET detector modules.We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard.The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverseaxis on both scanners (~1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals
机译:在这项工作中,我们比较了CIEMAT(西班牙马德里)安装的两种商用正电子发射断层扫描(PET)扫描仪:ClearPET和rPET-1。这些系统具有显着的几何差异,例如轴向视场(ClearPET上为110 mm,rPET-1上为45.6 mm),检测器的配置(ClearPET上的整个环与rPET-1上的一对平面模块)以及使用我们使用的评估程序符合美国国家电气制造商协会(NEMA)NU 4-2008标准的建议,该方法包括空间分辨率,灵敏度,散射分数,计数损耗和图像质量的研究。我们的实验表明,ClearPET的中心空间分辨率为1.5毫米(轴向),3.2毫米(轴向),rPET-1的中心空间分辨率为1.5毫米(轴向),1.6毫米(轴向),两个扫描仪的横向轴线上的变化很小(〜1毫米)。 ClearPET在视场中心的绝对灵敏度为4.7%,rPET-1为1.0%。鼠标大小的幻影的峰值噪声当量计数率在ClearPET上达到0.51 MBq / mL时为73.4 kcps,在rPET-1上以1.35 MBq / mL达到29.2 kcps。使用图像质量体模测量的恢复系数在ClearPET上为0.11至0.89,在rPET-1上为0.14至0.81。总体性能表明,ClearPET和rPET-1系统都非常适合于小动物的临床前研究和成像

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号