To develop a novel method for rapid myocardial T1 mapping at high spatial resolution. METHODS: The proposed strategy represents a single-shot inversion-recovery (IR) experiment triggered to early diastole during a brief breathhold. The measurement combines an adiabatic inversion pulse with a real-time readout by highly undersampled radial FLASH, iterative image reconstruction and T1 fitting with automatic deletion of systolic frames. The method was implemented on a 3 T MRI system using a GPU-equipped bypass computer for online application. Validations employed a T1 reference phantom including analyses at simulated heart rates from 40 to 100 bpm. In vivo applications involved myocardial T1 mapping in short-axis views of healthy young volunteers. RESULTS: At 1 mm in-plane resolution and 6 mm section thickness, the IR measurement could be shortened to 3 s without compromising T1 quantitation. Phantom studies demonstrated T1 accuracy and high precision for values ranging from 300 to 1500 ms and up to a heart rate of 100 bpm. Similar results were obtained in vivo yielding septal T1 values of 1246 ± 24 ms (base), 1256 ± 33 ms (mid-ventricular) and 1288 ± 30 ms (apex), respectively (mean ± SD, n=6). CONCLUSION: Diastolic myocardial T1 mapping with use of single-shot inversion-recovery FLASH offers high spatial resolution, T1 accuracy and precision, practical robustness and speed. Advances in knowledge: The proposed method will be beneficial for clinical applications relying on native and post-contrast T1 quantitation.
机译:要开发一种在高空间分辨率下快速进行心肌T1定位的新方法。方法:提出的策略代表了一次短暂的呼吸暂停时舒张早期触发的单次倒置恢复(IR)实验。该测量结合了绝热反转脉冲和通过高度欠采样的径向FLASH进行的实时读数,迭代图像重建和T1拟合以及收缩期帧的自动删除功能。该方法是在3 T MRI系统上使用配备GPU的旁路计算机进行在线应用的。验证采用了T1参考体模,包括在40至100 bpm的模拟心率下进行的分析。体内应用涉及健康年轻志愿者在短轴视图中进行的心肌T1定位。结果:在1mm的面内分辨率和6mm的截面厚度下,IR测量可以缩短至3s,而不会影响T1定量。幻影研究表明,T1精度和高精度适用于300到1500 ms范围内的值以及最高100 bpm的心率。体内获得相似的结果,间隔T1值分别为1246±24 ms(基础),1256±33 ms(心室中)和1288±30 ms(顶点)(平均值±SD,n = 6)。结论:舒张性心肌T1映射与单次反转恢复FLASH的使用提供了高空间分辨率,T1准确性和准确性,实用的鲁棒性和速度。知识方面的进步:所提出的方法将有助于依靠天然T1和对比后T1定量的临床应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号