首页> 外文OA文献 >MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods
【2h】

MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods

机译:基于mRI的全身pET / mRI衰减校正:基于分割和图谱的方法的定量评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PET/MRI is an emerging dual-modality imaging technology that requires new approaches to PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC (MRAC): a basic MR image segmentation algorithm and a method based on atlas registration and pattern recognition (ATPR). METHODS: Eleven patients each underwent a whole-body PET/CT study and a separate multibed whole-body MRI study. The MR image segmentation algorithm uses a combination of image thresholds, Dixon fat-water segmentation, and component analysis to detect the lungs. MR images are segmented into 5 tissue classes (not including bone), and each class is assigned a default linear attenuation value. The ATPR algorithm uses a database of previously aligned pairs of MRI/CT image volumes. For each patient, these pairs are registered to the patient MRI volume, and machine-learning techniques are used to predict attenuation values on a continuous scale. MRAC methods are compared via the quantitative analysis of AC PET images using volumes of interest in normal organs and on lesions. We assume the PET/CT values after CT-based AC to be the reference standard. RESULTS: In regions of normal physiologic uptake, the average error of the mean standardized uptake value was 14.1 ± 10.2 and 7.7 ± 8.4 for the segmentation and the ATPR methods, respectively. Lesion-based errors were 7.5 ± 7.9 for the segmentation method and 5.7 ± 4.7 for the ATPR method. CONCLUSION: The MRAC method using ATPR provided better overall PET quantification accuracy than the basic MR image segmentation approach. This better quantification was due to the significantly reduced volume of errors made regarding volumes of interest within or near bones and the slightly reduced volume of errors made regarding areas outside the lungs.
机译:PET / MRI是新兴的双模态成像技术,需要采用新方法进行PET衰减校正(AC)。我们评估了两种基于MRI的全身AC(MRAC)的算法:一种基本的MR图像分割算法和一种基于图谱配准和模式识别(ATPR)的方法。方法:11名患者均接受了全身PET / CT研究和一项单独的多床全身MRI研究。 MR图像分割算法使用图像阈值,Dixon脂肪水分割和成分分析的组合来检测肺部。 MR图像分为5个组织类别(不包括骨骼),每个类别都分配有默认的线性衰减值。 ATPR算法使用先前对齐的MRI / CT图像对对的数据库。对于每个患者,将这些对记录到患者的MRI体积中,并使用机器学习技术来连续预测衰减值。通过使用正常器官和病变部位感兴趣的体积对AC PET图像进行定量分析,比较了MRAC方法。我们假定基于CT的AC后的PET / CT值作为参考标准。结果:在生理摄取正常的区域中,分割和ATPR方法的平均标准摄取值的平均误差分别为14.1±10.2和7.7±8.4。分割方法的基于病变的误差为7.5±7.9,ATPR方法的基于病变的误差为5.7±4.7。结论:使用ATPR的MRAC方法比基本的MR图像分割方法提供了更好的总体PET定量准确性。更好的量化是由于关于骨骼内或附近的感兴趣区域的错误量显着减少以及关于肺外区域的错误量略有减少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号