首页> 外文OA文献 >Amino-​calixarene-​modified graphitic carbon as a novel electrochemical interface for simultaneous measurement of lead and cadmium ions at picomolar level
【2h】

Amino-​calixarene-​modified graphitic carbon as a novel electrochemical interface for simultaneous measurement of lead and cadmium ions at picomolar level

机译:氨基杯芳烃改性的石墨碳作为一种新型电化学界面,用于同步测量皮摩尔水平的铅和镉离子

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Amino-​calixarene-​derivatized graphitic carbon electrode has been used in the simultaneous quantification of lead and cadmium ions at picomolar level. The graphitic carbon has been chem. modified using amino-​calixarene as an indicator mol. through microwave irradn., and it has been characterized by NMR, mass, and Fourier transform IR spectroscopy (FTIR) techniques. The proposed sensor has shown linearity in the concn. range 10-​120 pM with detection limits of 3.3 and 3.5 pM for lead and cadmium, resp. The proposed sensor has been successfully applied to quantify lead and cadmium levels in battery effluents, alloy materials, and sewage water sample matrixes. The results obtained by the proposed sensor are in agreement with the results of the std. protocols.
机译:氨基杯芳烃衍生的石墨碳电极已用于同时定量皮摩尔级的铅和镉离子。石墨碳是化学的。使用氨基杯芳烃作为指示剂进行修饰。通过微波辐照,并且已通过NMR,质谱和傅立叶变换红外光谱(FTIR)技术进行了表征。所提出的传感器已经显示出线性关系。范围为10-120 pM,铅和镉的检出限分别为3.3和3.5 pM。所提出的传感器已成功应用于定量电池废水,合金材料和污水样品基质中的铅和镉含量。所提出的传感器获得的结果与std的结果一致。协议。