Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.
机译:肌酐是监测肾功能所必需的参数,对于接受潜在毒性肾脏药物(例如抗HIV药物替诺福韦)治疗的患者来说,重要的是要遵循肌酐。一种用于测量肌酐的护理点仪器对于在资源有限的环境中进行患者监测很有用,因为在这种情况下,无法使用更多复杂的仪器。评估了StatSensor Xpress肌酐(Nova生物医学合作公司,美国马萨诸塞州沃尔瑟姆市)的即时分析仪在指示药物治疗改变方面的诊断性能。使用Nova StatSensor Xpress肌酐分析仪和Vitros 5,1FS(美国罗彻斯特的Ortho Clinical Diagnostics,Inc)作为参考标准,并行测定肌酐。 StatSensor Xpress肌酐分析仪的精密度(即重复性和重现性)和准确性是使用一组具有正常,低病理和高病理值的标本来计算的。使用两个不同的Nova StatSensor Xpress肌酐分析仪通过重复测量来评估准确性。 StatSensor Xpress肌酐分析仪的变异系数重复性介于2.3至5.9%,两次运行之间的重复性介于4.2至9.0%。除了高值(> 600 µmol / L)外,一致性相关协议都很好。高病理标本中的Bland-Altman分析表明,Nova StatSensor Xpress肌酐测试倾向于低估高肌酐值(即> 600 µmol / L)。使用质量控制试剂,Nova StatSensor Xpress肌酐分析仪在重复性,设备间可重复性和两次运行之间的可重复性方面显示出令人满意的良好结果。发现该分析仪足够准确,可检测患者(年龄> 10岁)的病理学值,并且可以使用中度错误分类风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号