The performance of two different steel beam to column connec-tions known as SidePlateTM and a new proposed connection by seismic loading and progressive collapse were investigated in this research. Seismic performance evaluated included consideration of interstory drift angles and flexural strengths based on 2010 AISC Seismic Provisions while investigation of progressive collapse was conducted through satisfaction of acceptance criteria by rotational capacities of the connections provided in UFC 4-023-03 guideline. The results indicated that both SidePlate and the new proposed moment connection were capable of achieving adequate rotational capacity and developing full inelastic capacity of the connecting beam. Also, an excellent performance was exhibited by the con-nections in terms of keeping the plastic hinges away from the connection and exceeding interstory drift angle of 0.06 rad with-out fracture developments in beam flange groove-welded joints. Based on results, it was concluded that the SidePlate and the new proposed connection possess sufficient stiffness, strength and ductility to be classified as rigid, full-strength and ductile connections.
机译:在这项研究中,研究了两种不同的钢梁到立柱的连接性能,即SidePlateTM以及通过地震荷载和渐进倒塌提出的新连接方案。评估的抗震性能包括根据2010 AISC抗震规定考虑层间漂移角和抗弯强度,而渐进倒塌的调查则通过UFC 4-023-03指南中提供的连接件的旋转能力通过接受标准的满足来进行。结果表明,SidePlate和新提议的弯矩连接都能够实现足够的旋转能力,并充分发挥连接梁的无弹性能力。同样,在保持塑料铰链远离连接处和超过0.06 rad的层间漂移角方面,连接表现出了出色的性能,而在梁法兰槽焊接接头中没有出现断裂。根据结果​​,可以得出结论,SidePlate和新提议的连接具有足够的刚度,强度和延展性,可分为刚性,全强度和延性连接。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号