Modeling, simulation and design of an improved high power factor bridgeless sepic converter

机译:改进的高功率因数无桥Sepic转换器的建模,仿真和设计

摘要

Switch Mode Power Supply (SMPS) designs are normally have a power quality issues due to the harmonic distortion produce in the system. Therefore it is essential to incorporate a power factor correction (PFC) circuit in SMPS design. Although, the boost converter is more popular to use with PFC circuit, SEPIC converter can produce an input current with lower ripple value. However, since it involved with 4 energy storage component, a bridgeless SEPIC converter were used as the bridgeless circuit reduce the component conducted in ech switching cycle compared to conventional SEPIC. Therefore this thesis focuses on designing the bridgeless PFC SEPIC converter that operate in CCM with two types of controller. The controllers are Average Current Control Mode and Peak Current Control Mode. Simulation of the bridgeless SEPIC PFC circuit were done using MATLAB Simulink software. The results show that the Average Current Mode Control produce high power factor with low harmonic distortion compared to Peak Current Mode Control. At the end of this thesis, a suitable recommendation and suggestion were made to improve the project design
机译:由于系统中产生的谐波失真,开关模式电源(SMPS)设计通常存在电能质量问题。因此,在SMPS设计中合并功率因数校正(PFC)电路至关重要。尽管升压转换器更流行用于PFC电路,但SEPIC转换器可以产生具有较低纹波值的输入电流。然而,由于它涉及4个能量存储组件,因此与传统SEPIC相比,无桥SEPIC转换器被用作无桥电路,从而减少了在ech开关周期中传导的组件。因此,本论文着重于设计无桥PFC SEPIC转换器,该转换器在CCM中使用两种类型的控制器工作。控制器为平均电流控制模式和峰值电流控制模式。使用MATLAB Simulink软件对无桥SEPIC PFC电路进行了仿真。结果表明,与峰值电流模式控制相比,平均电流模式控制产生的功率因数高且谐波失真低。在本文的最后,提出了适当的建议和建议以改进项目设计。

著录项

  • 作者

    Mustafar Izni;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号