首页> 外文OA文献 >Correlation between reflectance and refractive index of different liquids using an optical time domain reflectometer (OTDR)
【2h】

Correlation between reflectance and refractive index of different liquids using an optical time domain reflectometer (OTDR)

机译:使用光学时域反射仪(OTDR)的不同液体的反射率和折射率之间的相关性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Recently, the area of measurement and instrumentation and particularly sensor development has undergone fast development. Among the active advancement of sensor based microelectronics development, the optical based sensor has expanded promisingly over these past years due to its key advantages such as compact size, low power consumption, corrosion and electrical spark free which would cause a fire in the explosive environment, electromagnetic interference proof, high sensitivity and large distance between signal detection that is possibility of enabling a long distance measurements. For instance, refractive index sensors have attracted considerable attention in biological and chemical applications. Thus many optical sensors for refractive index (RI) detection have been proposed. Therefore, this research was carried out in order to seek the correlation between reflectance and refractive index of different liquids using an optical time domain reflectometer (OTDR) via single mode fibre (SMF) of 100m length. There are three objectives that are to observe the fluctuation in the fiber end of the five liquids (water, acetic acid, 1-butanol, 1-octyne and ethyl glycol with their corresponding RI are 1.33, 1.337, 1.40, 1.42 and 1.43), to clarify experimentally the correlation between reflectance with RI of the liquids and to analyze the potential of using the OTDR technique for measurement RI of liquids. Each liquid is measured 10 times in order to obtain good average value of reflectance reading under three different pulse widths (20ns, 50ns and 100ns). After completing the data analysis, the fluctuations in reflection readings of the liquids is within 6%. The experimental and simulation curves are similar in trend and the OTDR technique has the potential in measuring RIs of liquids.
机译:近来,测量和仪器领域,特别是传感器的开发领域发展迅速。在基于传感器的微电子技术的积极发展中,基于光学的传感器在过去的几年中取得了令人鼓舞的发展,这是由于其主要优点,例如体积小,功耗低,无腐蚀和无电火花,这会在爆炸性环境中引起火灾,防电磁干扰,高灵敏度以及信号检测之间的较大距离,这使得能够进行长距离测量。例如,折射率传感器在生物和化学应用中引起了相当大的关注。因此,已经提出了许多用于折射率(RI)检测的光学传感器。因此,为了通过使用光学时域反射仪(OTDR)通过100m长的单模光纤(SMF)来寻找不同液体的反射率和折射率之间的相关性,进行了这项研究。有三个目的是观察五种液体的纤维末端的波动(水,乙酸,1-丁醇,1-辛炔和乙二醇,其相应的RI为1.33、1.337、1.40、1.42和1.43),通过实验澄清液体反射率与RI之间的相关性,并分析使用OTDR技术测量液体RI的潜力。对每种液体进行10次测量,以在三个不同的脉冲宽度(20ns,50ns和100ns)下获得良好的反射率平均值。完成数据分析后,液体反射读数的波动在6%以内。实验和模拟曲线趋势相似,OTDR技术具有测量液体RI的潜力。

著录项

  • 作者

    Hashim Sapull Nizam;

  • 作者单位
  • 年度 2013
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号