This paper presents an improved stator flux estimation technique based on a voltage model with some form of low-pass (LP) filtering. In voltage-model-based stator flux estimation, an LP filter is normally used instead of a pure integrator to avoid integration drift problem due to DC offset, noise, or measurement error present in the back electromotive force. In steady-state condition, the LP filter estimator will degrade the performance and efficiency of the direct torque control (DTC) drive system since it introduced magnitude and phase errors, thus resulting in an incorrect voltage vector selection. The stator flux steady-state error between the LP filter and a pure integrator estimator technique is derived and its effect on the steady-state DTC drive performance is analyzed. A simple method is proposed to compensate for this error which results in a significant improvement in the steady-state drive performance. Simulation based on this technique is given and it is verified by experimental resultsud
机译:本文提出了一种改进的基于电压模型的定子磁链估计技术,该模型具有某种形式的低通(LP)滤波。在基于电压模型的定子磁通估计中,通常使用LP滤波器代替纯积分器,以避免由于直流偏移,噪声或反电动势中存在的测量误差而引起的积分漂移问题。在稳态条件下,由于LP滤波器估算器引入了幅度和相位误差,因此会降低直接转矩控制(DTC)驱动系统的性能和效率,从而导致错误的电压矢量选择。推导了LP滤波器和纯积分估计器技术之间的定子磁通稳态误差,并分析了其对稳态DTC驱动性能的影响。提出了一种简单的方法来补偿该误差,从而导致稳态驱动性能的显着改善。给出了基于该技术的仿真,并通过实验结果进行了验证 ud

著录项

  • 作者

    Idris N. R. N.; Yatim A. H. M.;

  • 作者单位
  • 年度 2002
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"english","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号