A gas burner system applying water cooling heat exchanger has been investigated using a 140 mm inside diameter combustor of 294 mm length. The combustor was placed vertically upwards All tests were coducted using natural gas only. A fixed straight blade radial swirler with 76 mm outlet diameter was placed at the inlet plane of the combustor. An orifice plate of 59 mm was inserted at the exist plane of the swirler to enhance turbulence and help in mixing of the fuel and air. Fuel was injected at the back plate of the swirler using central fuel injector with eight fuel holes ponted radially outward. Tests were conducted at 2 mmW.G. pressure loss. A reduction of about 20 per cent on NOx emissions was achieved at equivalence ratio of near stoichiometric (0.9). Other emissions such as carbon monoxide were well under 100 ppm except below equivalence ratio of near 0.5 due to cooling effect. Unburned hydrocarbon emissions were well below 10 ppm except below equivalence ratio of 0.5.
机译:使用140毫米长,294毫米长的内径燃烧器研究了应用水冷式热交换器的燃气燃烧器系统。将燃烧器垂直向上放置。所有测试仅使用天然气进行。将固定直径为76 mm的直叶片径向旋流器固定在燃烧室的入口平面。在旋流器的存在平面处插入一个59 mm的孔板,以增强湍流并帮助燃料和空气混合。使用中央燃油喷射器将燃油喷射到旋流器的后板上,其中八个燃油孔径向向外伸出。试验在2mmW.G下进行。压力损失。在接近化学计量当量比(0.9)时,NOx排放量减少了约20%。一氧化碳等其他排放物由于冷却效果而低于当量比接近0.5时远低于100 ppm。未燃烧的碳氢化合物排放量远低于10 ppm,但低于0.5的当量比。