首页> 外文OA文献 >Degradation assessment of nuclear power plant extraction steam piping after long term service
【2h】

Degradation assessment of nuclear power plant extraction steam piping after long term service

机译:长期服务后核电站抽汽管道的降解评估

摘要

Degradation due to ageing in a Nuclear Power Plant’s Extraction Steam Piping has been assessed. Samples of twelve years old seamless carbon steel SA 106B pipe have been taken and subjected to metallographic examination, hardness testing, radiographic examination and ultrasonic thickness measurement to investigate and analyze ageing in piping material. Metallographic examination of aged sample revealed irregularly distributed graphite nodules in ferrite grains and on grain boundaries as well, the reduction in pearlite phase has also been observed from 40% to 25%. This Transformation in microstructure has reduced hardness of steel. Reduction in hardness has found 20.4% and 0.7% on inner and outer layer of the pipe material respectively. Corrosion pits having average depth of 0.07 mm have been found on external surface. Radiograph of aged pipe revealed material removal and wall thinning due to erosion on inner surface of pipe. The extent of erosion had been checked, which has found 8.7%.
机译:已经评估了由于核电站的抽汽管道老化导致的退化。采集了十二年老的无缝碳钢SA 106B管的样品,并对其进行了金相检查,硬度测试,射线照相检查和超声厚度测量,以调查和分析管道材料的老化情况。老化试样的金相检查发现,在铁素体晶粒中以及在晶界上石墨颗粒的分布不规则,珠光体相的减少也从40%降至25%。微观结构的这种转变降低了钢的硬度。发现在管道材料的内层和外层上的硬度降低分别为20.4%和0.7%。在外表面上发现了平均深度为0.07mm的腐蚀坑。老化管道的X射线照片显示,由于管道内表面的腐蚀,材料被去除并且壁变薄。已检查侵蚀程度,发现为8.7%。