High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) is small electrical sparks present in an insulator as result of the electrical breakdown of a gas (for example air) contained within a void or in a highly nonuniform electric field. Partial discharge (PD) phenomenon is one of the reasons that happen in high voltage appliances and lead to failure of power transformer, leading to expensive repair and power outage. An acoustic emission (AE) phenomenon also happens near the discharge zone that is used to detect (PD).Partial discharge detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. Many researchers have used acoustic emissions (AE) at the vicinity of the discharge zones to detect PD. This project compares the sensitivity of single mode fiber optical sensor with capacitive sensor. The fiber optical sensor (FOS) and capacitive sensor were immersed in an oil tank fitted with two steel electrodes which were connected to different values of high voltage source. The data obtained by both sensors were then analyzed in time and frequency domain, and compared by peak analysis that suggest that single mode optical fiber was able to act as acoustic sensor with large wide band of signals. These experimental results are interesting which also suggest that both sensors have peculiar characteristics for the detection of AE and could be used as per the PD detection requirements.
机译:为了确保系统的稳定性,高压变压器是电力系统网络中最关键和最昂贵的组件。局部放电(PD)是绝缘体中存在的小电火花,这是空隙或高度不均匀电场中所含气体(例如空气)发生电击穿的结果。局部放电(PD)现象是高压电器中发生并导致变压器故障,导致昂贵的维修和停电的原因之一。声发射(AE)现象也发生在用于检测(PD)的放电区域附近。局部放电检测是一种广泛用于高压设备绝缘状况监视和评估的技术。许多研究人员已在放电区域附近使用声发射(AE)检测PD。该项目将单模光纤传感器与电容传感器的灵敏度进行了比较。将光纤传感器(FOS)和电容式传感器浸入装有两个钢电极的油箱中,这两个钢电极分别连接到不同的高压源上。然后,在时域和频域对这两个传感器获得的数据进行了分析,并通过峰分析进行了比较,这表明单模光纤能够充当具有大宽带信号的声传感器。这些实验结果很有趣,这也表明这两个传感器都具有用于AE检测的独特特性,并且可以根据PD检测要求使用。

著录项

  • 作者

    Khallawi Alaa Razzaq;

  • 作者单位
  • 年度 2014
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号