首页> 外文OA文献 >A method for evaluating the heat and mass transfer characteristics in a reversibly used water cooling tower (RUWCT) for heat recovery
【2h】

A method for evaluating the heat and mass transfer characteristics in a reversibly used water cooling tower (RUWCT) for heat recovery

机译:一种用于可热回收的可逆使用的水冷却塔(RUWCT)中传热和传质特性的评估方法

摘要

In sub-tropical regions, a standard water cooling tower may be reversibly used, as part of a desuperheater heat recovery system for service hot water heating, to extract free heat from ambient air in colder seasons when building cooling load is reduced. Chilled water is pumped into a reversibly used water cooling tower (RUWCT) where it is heated by warmer ambient moist air. This paper presents a method by which the heat and mass transfer characteristics in a counter-flow RUWCT can be evaluated. The method is developed by introducing to the Merkel's equation for standard water cooling towers the revisions that account for the differences in heat and mass transfer characteristics between a water cooling tower and a RUWCT. Field experimental results from a RUWCT installed in a sub-tropical region in China indicated that the method developed could be used to evaluate the thermal performance of a RUWCT with an acceptable accuracy.
机译:在亚热带地区,可将标准的水冷却塔可逆地使用,作为用于服务热水加热的减温器热回收系统的一部分,以在建筑物冷负荷减少时的较冷季节从环境空气中提取自由热量。冷冻水被泵送到可逆使用的水冷却塔(RUWCT)中,并在其中被温暖的环境潮湿空气加热。本文提出了一种方法,通过该方法可以评估逆流RUWCT中的传热和传质特性。通过向标准水冷却塔的默克尔方程中引入修正值来开发该方法,该修正考虑了水冷却塔和RUWCT之间的传热和传质特性差异。安装在中国亚热带地区的RUWCT的现场实验结果表明,所开发的方法可用于以可接受的精度评估RUWCT的热性能。

著录项

  • 作者

    Tan K; Deng S;

  • 作者单位
  • 年度 2002
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有