摘要

A simple model is proposed to calculate the air temperature in a compartmental fire with forced ventilation. The model is based on the mixing process in displacement ventilation theory. This is reasonable as the air intake rate in a forced ventilation chamber can be fixed at a certain value. Expressions for the hot air temperature are derived by considering the cases with and without a plume region. Experimental studies in a small chamber with forced ventilation were performed to verify the predicted results.
机译:提出了一个简单的模型来计算强制通风的隔室火中的空气温度。该模型基于置换通风理论中的混合过程。这是合理的,因为强制通风室内的进气速率可以固定为某个值。热空气温度的表达式是通过考虑带有或不带有羽流区域的情况得出的。在带有强制通风的小室内进行实验研究以验证预测结果。