摘要

An automatic elastic medical image registration approach is proposed, based on image intensity. The algorithm is divided into two steps. In Step 1, global affine registration is first used to establish an initial guess and the resulting images can be assumed to have only small local elastic deformations. The mapped images are then used as inputs in Step 2, during which, the study image is modeled as elastic sheet by being divided into sub-images. Moving the individual sub-image in the reference image, the local displacement vectors are found and the global elastic transformation is achieved by assimilating all of the local transformation into a continuous transformation. The algorithm has been validated by simulated data, noisy data and clinical tomographic data. Both experiments and theoretical analysis have demonstrated that the proposed algorithm has a superior computational performance and can register images automatically with an improved accuracy.
机译:提出了一种基于图像强度的自动弹性医学图像配准方法。该算法分为两个步骤。在步骤1中,首先使用全局仿射配准来建立初始猜测,并且可以假定所得图像仅具有较小的局部弹性变形。然后,在步骤2中将映射的图像用作输入,在此期间,通过将研究图像划分为子图像,可以将研究图像建模为弹性片。在参考图像中移动单个子图像,找到局部位移矢量,并通过将所有局部变换同化为连续变换来实现全局弹性变换。该算法已通过仿真数据,噪声数据和临床断层扫描数据进行了验证。实验和理论分析均表明,该算法具有较高的计算性能,可以自动配准图像,且精度更高。