首页> 外文OA文献 >Automatic descending aorta segmentation in whole-body PET-CT studies for PERCIST-based thresholding
【2h】

Automatic descending aorta segmentation in whole-body PET-CT studies for PERCIST-based thresholding

机译:全身PET-CT研究中基于PERCIST的阈值自动降主动脉分割

摘要

Medical imaging is a fundamental component of modern healthcare where majority of medical conditions can benefit from some kinds of imaging. A dual-modal positron emission tomography - computed tomography (PET-CT) has increasingly become the preferred imaging method to stage the common cancers and to assess treatment response. For example, PET image can quantitatively assess the treatment before morphological changes that can be detected on anatomical CT image. PET response criterion (PERCIST) is a widely recognised thresholding method for detecting malignant lesions (high metabolic value) in treatment response. It is based on the calculation of standardised uptake value with lean body mass (SUVLBM), together with a volume of interest (VOI) reference placed on the right lobe of the liver or the descending aorta (when the liver is abnormal e.g., liver cancer). These two structures are considered to have stable metabolism among the PET patient population and therefore can be used to normalise the SUV. The current practice of PERCIST thresholding depends on the manual delineation of the VOI reference which is a time consuming and operator-dependent process. Furthermore, such VOI selection is more difficult on the smaller descending aorta structure when compared to the liver. In this study, we propose a fully automatic approach to the segmentation of the descending aorta for use in the calculation of the PERCIST thresholding. A multi-atlas registration coupled with weighted decision function was used in the whole-body CT for the segmentation of the descending aorta, with the resulting VOI reference mapped to the co-aligned PET counterpart. We evaluated our method with 30 clinical PET-CT studies with preliminary results demonstrating reliability and robustness.
机译:医学成像是现代医疗保健的基本组成部分,其中大多数医学状况都可以从某些成像中受益。双模式正电子发射断层扫描-计算机断层扫描(PET-CT)日益成为分期常见癌症和评估治疗反应的首选成像方法。例如,PET图像可以在可以在解剖CT图像上检测到的形态变化之前定量评估治疗。 PET反应标准(PERCIST)是一种广为人知的阈值检测方法,用于检测治疗反应中的恶性病变(高代谢值)。它基于瘦体重的标准摄取值(SUVLBM)以及放置在肝右叶或降主动脉上的感兴趣体积(VOI)参考值的计算(当肝异常时,例如肝癌) )。这两个结构被认为在PET患者人群中具有稳定的新陈代谢,因此可以用来使SUV正常化。 PERCIST阈值化的当前实践取决于VOI参考的手动描述,这是一个耗时且依赖于操作员的过程。此外,与肝脏相比,在较小的降主动脉结构上,这样的VOI选择更加困难。在这项研究中,我们提出了一种用于降主动脉分割的全自动方法,用于PERCIST阈值的计算。在全身CT中使用多图谱配准和加权决策函数对降主动脉进行分割,并将最终的VOI参考映射到同向对齐的PET对应物。我们通过30项临床PET-CT研究评估了我们的方法,初步结果证明了其可靠性和耐用性。

著录项

  • 作者

    Bi L; Kim J; Wen LF; Feng D;

  • 作者单位
  • 年度 2012
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号