首页> 外文OA文献 >Using a commercial partial discharge detector to investigate ac corona in air
【2h】

Using a commercial partial discharge detector to investigate ac corona in air

机译:使用商用局部放电检测器研究空气中的交流电晕

摘要

A computer-based commercial partial discharge detector has been used to measure ac corona pulses in a point/cup electrode system, in air. The pulse height distribution was measured as a function of phase angle and pulse height for a range of voltages. The onset voltages for both positive and negative half-cycles are the same, but slightly lower than for the dc case, due to space charge effects. In all other respects the patterns for the two half-cycles are different: pulses only occur at the onset voltage (rising) for the positive half-cycle; but continuously from 11 kV (rising) to 14 kV (falling) for the negative half-cycle. Differences between the distributions for avalanches and streamers increase as the breakdown voltage is approached. Qualitative explanations of the patterns and behavior are given
机译:基于计算机的商用局部放电检测器已用于测量空气中点/杯电极系统中的交流电晕脉冲。对于一定范围的电压,测量脉冲高度分布作为相角和脉冲高度的函数。正负半周的起始电压相同,但由于空间电荷效应,其起始电压略低于直流情况。在所有其他方面,两个半周期的模式是不同的:仅在正半周的起始电压(上升)出现脉冲;但对于负半周期,从11 kV(上升)到14 kV(下降)连续不断。随着接近击穿电压,雪崩和拖缆的分布之间的差异增加。给出了模式和行为的定性解释