The smoke aspects in the escape routes for a three-level apartment are studied using the fire zone model CFAST 2.0. The smoke temperature and smoke layer interface heights in the corridors and staircases are analyzed. Performance of smoke control systems including ceiling vents (vent size of 1-4 m2) and smoke extraction systems (one to six air changes per hour) installed in the staircase are evaluated. Some experimental results reported in the literature are used to compare with the results predicted by this model. Finally, the effect of installing a residential sprinkler were discussed. Simulations on the fire suppression effect of residential sprinkler were performed using the fire protection engineering tool FASTLite with unsteady t2-fires. A comparison on the heat release rate of the smoke layer temperature for the cases with and without a sprinkler was made.
机译:使用防火区域模型CFAST 2.0研究了三层公寓逃生路线中的烟雾情况。分析了走廊和楼梯中的烟气温度和烟气层界面高度。评估了安装在楼梯上的烟雾控制系统(包括天花板通风孔(通风口大小为1-4平方米)和排烟系统(每小时换气1至6次)的性能。文献中报道的一些实验结果用于与该模型预测的结果进行比较。最后,讨论了安装住宅洒水器的效果。使用具有不稳定t2-fires的消防工程工具FASTLite对住宅洒水装置的灭火效果进行了仿真。比较有无洒水器情况下烟层温度的放热率。