摘要

A simplified Neumann's formula to calculate the inductance of a transformer with spiral shape is proposed. The advantage of using the proposed method is to avoid the cumbersome and tedious integration in Neumann's formula; the solution usually includes elliptic functions that are complicated and long power series. The stray capacitance of the transformer is also calculated. The experimental measurement agrees well with the calculation.
机译:提出了一种简化的诺伊曼公式,用于计算螺旋形变压器的电感。使用该方法的优点是避免了诺伊曼公式中繁琐而繁琐的积分。该解决方案通常包括复杂的椭圆函数和长幂级数。还计算了变压器的杂散电容。实验测量结果与计算结果吻合良好。