首页> 外文OA文献 >A proposed fire safety ranking system for karaoke establishments and its comparison with the NFPA-fire safety evaluation system
【2h】

A proposed fire safety ranking system for karaoke establishments and its comparison with the NFPA-fire safety evaluation system

机译:拟议的卡拉OK场所消防安全等级系统及其与NFPA-消防安全评估系统的比较

摘要

A fire safety ranking system (FSRS), excluding the fire safety management at the moment, is proposed for assessing the fire safety provisions for existing karaoke establishments in Hong Kong. The objective is to investigate how far existing karaokes deviate from the expectation of new codes. Suitable fire safety management can then be worked out based on the scores. There are three attributes in the FSRS grouped as the key parameters for local fire safety requirements, passive building design and active fire protection systems. From the results of a survey carried out in May 2000, fire safety of 19 karaokes is rated by studying their architectural features and interior details. The results are compared with those by the National Fire Protection Association-Fire Safety Evaluation System (NFPA-FSES) on the part on fire safety parameters. Apart from dealing with fire spreading for interior finish, the proposed FSRS and NFPA-FSES are similar. The study of 19 of the existing karaoke establishments shows that the assessed level of fire safety is similar to the result of an assessment using the modified American system of evaluation.
机译:建议采用一种消防安全等级制度(FSRS),不包括目前的消防安全管理,以评估香港现有卡拉OK场所的消防安全规定。目的是调查现有卡拉OK与新规范的期望有多大差异。然后可以根据分数制定适当的消防安全管理措施。 FSRS中分为三个属性,分别是当地消防安全要求,被动式建筑设计和主动式消防系统的关键参数。根据2000年5月进行的一项调查结果,通过研究19卡拉OK的建筑特征和内部细节对其消防安全性进行了评级。将结果与美国国家消防协会消防安全评估系统(NFPA-FSES)的消防安全参数进行了比较。除了处理内部装饰的蔓延之外,建议的FSRS和NFPA-FSES相似。对19个现有卡拉OK场所的研究表明,评估的消防安全水平与使用改良的美国评估系统进行评估的结果相似。

著录项

  • 作者

    Chow WK; Lui GCH;

  • 作者单位
  • 年度 2002
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号