首页> 外文OA文献 >Analytical solution for the full-range pull-out behavior of FRP ground anchors
【2h】

Analytical solution for the full-range pull-out behavior of FRP ground anchors

机译:FRP地锚全范围拉拔行为的解析解

摘要

This paper attempts to predict the nonlinear pull-out response of fiber reinforced polymer (FRP) rods embedded in steel tubes filled with cement grout. Based on a tri-linear bond-slip model, the whole FRP rod is divided into three zones: linear elastic, softening, and frictional. In each zone, a set of two second-order ordinary differential equations are established in terms of the displacements of the FRP rod and steel tube and solved in an analytical manner. When the thickness of the steel tube approaches infinity, the solution can be applied to the problem of FRP rods embedded in rock. Based on the derived solution, the interfacial bond properties and snapback phenomenon are discussed. After the analytical solution is validated by comparisons with four sets of experimental data, the effects of the radius and length of FRP rods, the local peak bond stress and the residual frictional strength on the maximum pull-out load are evaluated through sensitivity analysis.
机译:本文试图预测埋入水泥浆的钢管中的纤维增强聚合物(FRP)棒的非线性拔出响应。基于三线性粘结滑移模型,整个FRP杆分为三个区域:线性弹性,软化和摩擦。在每个区域中,根据FRP杆和钢管的位移建立了两个二阶常微分方程组,并以解析方式求解。当钢管的厚度接近无穷大时,该解决方案可以应用于埋在岩石中的FRP杆的问题。基于导出的解,讨论了界面键的性质和回弹现象。通过与四组实验数据进行比较,验证了分析方法的有效性,然后通过敏感性分析评估了FRP杆的半径和长度,局部峰值粘结应力和残余摩擦强度对最大拉拔载荷的影响。