首页>
外文OA文献
>Local web buckling strength of coped steel I beams
【2h】
Local web buckling strength of coped steel I beams
展开▼
机译:涂覆I型钢梁的局部腹板屈曲强度
展开▼
免费
页面导航
摘要
著录项
引文网络
相似文献
相关主题
摘要
When a beam flange is coped to allow clearance at the connection, the strength of the coped region will be reduced. Local web buckling at the coped region may occur when the cope length is long and/or the compression flange is braced. Experimental and analytical investigation of the strength of coped steel I beams were conducted by a number of researchers and design formula was also proposed. However, the proposed formula underestimates the local web buckling capacity of a coped I beam, especially when the cope-depth to beam-depth ratio is small. To improve this discrepancy, full-scale tests of the web buckling strength of coped steel I beams and a series of analytical studies were carried out. A modified plate buckling formula, which considers the shear buckling phenomenon at the coped region, is proposed. The modified formula gives a better prediction of the local web buckling strength of a coped I beam. The test-to-predicted ratios varies from 0.92 to 1.06.
展开▼