首页> 外文OA文献 >Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water
【2h】

Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water

机译:基于中性或带电载体的固态接触式PVC膜电极,用于阴离子磺胺甲恶唑的选择性读取及其在水产养殖水中的分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.
机译:磺胺甲恶唑(SMX)是出于预防和治疗目的而在水产养殖中使用的抗生素之一。通过在鱼类养殖的多个阶段控制其水平,可以防止环境和食品传播。为此,本工作提出了新的SMX选择性电极,用于电位测定水中的磺酰胺。选择性膜由聚氯乙烯(PVC)和四苯基卟啉锰(III)氯化物或基于环糊精的离子载体制成。使用2-硝基苯基辛基醚作为增塑剂,使用四辛基铵,溴化二甲基二辛基氰基铵或四(4-氯苯基)硼酸钾作为阴离子或阳离子添加剂。据报道,与离子载体相比,四苯基卟啉锰(III)氯化物与50%摩尔四(4-氯苯基)硼酸钾的ISE的分析性能最佳。 Nersntian行为在4.0××10-5至1.0××10-2-2mol / L(10.0至2500μg/ mL)范围内,检出限为1.2××10-5-5mol / L(3.0μg/ mL)。通常,电极在6至9的pH范围内显示稳定的电势。在所有浓度水平下15s之前,电动势均达到平衡。电极显示出对环境样品的良好识别能力。对污染水的分析应用表明回收率为96%至106%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号