Rapid ion chromatography of L -ascorbic acid, nitrite, sulfite, oxalate, iodide and thiosulfate by isocratic elution utilizing a postcolumn reaction with cerium(IV) and fluorescence detection

机译:L-抗坏血酸,亚硝酸盐,亚硫酸盐,草酸盐,碘化物和硫代硫酸盐的快速离子色谱法,通过与铈(IV)的柱后反应和荧光检测等度洗脱

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Rapid separation and determination of mixtures of Image -ascorbic acid, nitrite, sulfite, oxalate, iodide and thiosulfate by conventional ion chromatography is often difficult due to incomplete separation of Image -ascorbic acid and nitrite from the water peak when using eluents giving short elution times for iodide and thiosulfate. Separation of the six species within about 15 min has been achieved by isocratic elution using a resin-based ion-exchange column with a carbonate eluent containing a trace amount of 1,3,5-benzenetricarboxylic acid (BTA) and fluorescence measurement of cerium(III) formed via postcolumn reactions of the separated sample species with cerium(IV). Calibration plots of peak height versus concentration were linear up to 10.0 μM (1.76 ppm) for Image -ascorbic acid, 8.0 μM (0.37 ppm) for nitrite, 8.0 μM (0.70 ppm) for oxalate, 80.0 μM (10.2 ppm) for iodide and 25.0 μM (2.80 ppm) for thiosulfate, whilst the sulfite calibration was linear up to 25.0 μM (2.00 ppm) when peak area was plotted against concentration. Detection limits (defined as S/N=3) were 18 ppb for Image -ascorbic acid, 4 ppb for nitrite, 16 ppb for sulfite, 7 ppb for oxalate, 72 ppb for iodide and 37 ppb for thiosulfate. The proposed method was applied successfully to the determination of Image -ascorbic acid, nitrite, sulfite, oxalate, iodide or thiosulfate in water samples.
机译:由于使用洗脱时间短的洗脱液无法从水峰中完全分离出图像抗坏血酸和亚硝酸盐,通常很难通过常规离子色谱法快速分离和测定图像抗坏血酸,亚硝酸盐,亚硫酸盐,草酸盐,碘化物和硫代硫酸盐的混合物。用于碘化物和硫代硫酸盐。通过使用基于树脂的离子交换柱和含有痕量1,3,5-苯三甲酸(BTA)的碳酸盐洗脱液的等离子洗脱以及铈的荧光测量,可以在约15分钟内分离出6种物质。 III)是通过分离的样品物种与铈(IV)的柱后反应而形成的。图像高度抗坏血酸的峰高与浓度的校准图呈线性关系,高达10.0μM(1.76 ppm),亚硝酸盐为8.0μM(0.37 ppm),草酸盐为8.0μM(0.70 ppm),碘化物为80.0μM(10.2 ppm)硫代硫酸盐为25.0μM(2.80 ppm),而峰面积相对于浓度作图时,亚硫酸盐校准线性最高至25.0μM(2.00 ppm)。图像抗坏血酸的检测限(定义为S / N = 3)为18 ppb,亚硝酸盐为4 ppb,亚硫酸盐为16 ppb,草酸盐为7 ppb,碘化物为72 ppb,硫代硫酸盐为37 ppb。该方法已成功应用于水样中图像抗坏血酸,亚硝酸盐,亚硫酸盐,草酸盐,碘化物或硫代硫酸盐的测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号