In this paper, voltage sag compensation of point of common coupling (PCC) using a new structure of fault current limiter (FCL) is proposed. The proposed structure prevents voltage sag and phase-angle jump of the substation PCC after fault occurrence. This structure has a simple control method. Using the semiconductorudswitch (insulated-gate bipolar transistor or gate turnoff thyristor at dc current rout leads to fast operation of the proposed FCL and, consequently, dc reactor value is reduced. On the other hand, the proposed structure reduces the total harmonic distortion on load voltage and it has low ac losses in normal operation. As a result, other feeders, which are connected to the substation PCC, will have good power quality. Analytical analysis and simulation results using PSCAD/EMTDC software and experimental results are presented to validate the effectiveness of this structure.
机译:本文提出了一种使用故障限流器(FCL)的新结构的公共耦合点(PCC)的电压骤降补偿。所提出的结构防止了变电站PCC在发生故障后的电压骤降和相角跳变。这种结构具有简单的控制方法。在直流电流rout下使用半导体 udswitch(绝缘栅双极型晶体管或栅截止晶闸管)可以使所提出的FCL快速运行,从而降低了直流电抗器的值。另一方面,所提出的结构也降低了总谐波失真负载电压,在正常运行中交流损耗低,因此,连接到变电站PCC的其他馈线将具有良好的电能质量,并使用PSCAD / EMTDC软件进行了分析和仿真结果以及实验结果,验证此结构的有效性。