Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature

机译:通过眼反应分析仪测量的角膜生物力学特性及其与眼内压和角膜中央曲率的关系

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: The aim of this study was to investigate the biomechanical properties of thecornea and their association with intraocular pressure (IOP), central corneal thickness(CCT) and the central corneal radius of curvature (Rc).Methods: Eighty-three eyes were divided into two groups. The biomechanical propertiesof the cornea were measured in 63 normal eyes and in 20 post-laser in situ keratomileusis(LASIK) eyes. The IOP, corneal hysteresis (CH) and corneal resistance factor (CRF) weremeasured by the Ocular Response Analyzer (ORA). The Rc and CCT were measuredusing the corneal topographer Medmont E-300 and the Tomey SP-100 Handy ultrasonicpachymeter. Other parameters measured by the ORA, such as TimeIn and TimeOut,were also studied.Results: A mean corneal hysteresis of 10.8 mmHg and CRF of 10.6 mmHg were recordedfor the normal eyes. There was no significant association with central curvature. Allparameters measured by the ORA showed a significant correlation with the CCT, exceptfor the corneal-compensated intraocular pressure (IOPcc). Both IOPs measured by theORA had the same values for the mean CH and CRF. For the post-LASIK eyes, the CHand CRF were lower than in the normal non-operated eyes. The TimeIn and theTimeOut also presented lower values for the post-LASIK eyes, suggesting that additionaldata can be obtained with the ORA measurements.Conclusions: The results of this study indicate that there is no correlation between theparameters measured with the Ocular Response Analyzer and central corneal radius ofcurvature. Some of the biomechanical properties of the cornea studied were found todiffer in the normal eyes compared to the post-LASIK eyes.
机译:背景:本研究的目的是研究角膜的生物力学特性及其与眼内压(IOP),中央角膜厚度(CCT)和中央角膜曲率半径(Rc)的关系。方法:分为83只眼睛分为两组在63只正常眼和20只激光后原位角膜磨镶术(LASIK)眼中测量了角膜的生物力学特性。通过眼响应分析仪(ORA)测量IOP,角膜滞后(CH)和角膜抵抗因子(CRF)。使用角膜地形图仪Medmont E-300和Tomey SP-100 Handy超声测厚仪测量Rc和CCT。结果:正常眼的平均角膜滞后为10.8 mmHg,CRF为10.6 mmHg。与中心曲率没有显着关联。除角膜补偿眼压(IOPcc)外,ORA测量的所有参数均显示与CCT显着相关。通过ORA测量的两个IOP的平均CH和CRF值相同。对于LASIK术后眼睛,CHand CRF低于正常非手术眼。 TimeIn和TheTimeOut也为LASIK后的眼睛提供了较低的值,表明可以通过ORA测量获得更多数据。结论:本研究结果表明,使用眼动分析仪测量的参数与角膜中央膜之间没有相关性曲率半径。与LASIK手术后的眼睛相比,正常眼中发现的角膜的某些生物力学特性有所不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号