This paper presents a rail power conditioner (RPC) system based on an indirect AC/DC/AC modular multilevel converter (MMC) where a V/V power transformer is used to feed the main catenary line and the locomotives. The proposed control strategy for this system has been introduced to guarantee a good compensating performance of negative sequence currents (NSCs) and harmonics on the public grid side. This control strategy has also the ability to achieve balanced and equal voltage between the MMC’s submodules (SMs) capacitors. Simulation results for this RPC based on an indirect MMC are presented in this paper to show the main advantages of using this topology. The results show how the proposed system is able to compensate NSCs and harmonics on the public grid side when the V/V power transformer feeds two unequal load sections.
机译:本文介绍了一种基于间接AC / DC / AC模块化多电平转换器(MMC)的铁路功率调节器(RPC)系统,其中使用V / V电力变压器为主悬链线和机车供电。已经引入了针对该系统的建议控制策略,以确保公共电网侧的负序电流(NSC)和谐波具有良好的补偿性能。这种控制策略还能够在MMC的子模块(SMs)电容器之间实现平衡且相等的电压。本文介绍了基于间接MMC的RPC的仿真结果,以显示使用此拓扑的主要优点。结果表明,当V / V电源变压器给两个不相等的负载部分供电时,所提出的系统如何能够补偿公共电网侧的NSC和谐波。