Wind tunnel tests are a reliable tool to determine the effect of natural ventilation onbuildings. This paper presents results of wind tunnel tests conducted to evaluate the influenceof ventilation modules positioning on a façade system. Modules positioning was modified,resulting in different façade configurations. The tests were carried out with the use of a model,varying the position of the ventilation modules in the façade configuration. The cases testedwere six ventilation modules positioned below the window-sill (ventilated window-sill), andthree ventilation modules positioned above and below the façade. The façade system proposedwas movable and interchangeable so that the same basic model could be used to test thepossibilities for ventilation. Wind speed measurements were taken inside and outside the modelfor the different façades configurations to evaluate the best performance in relation to naturalventilation. Singleâ sided and Cross ventilation were considered for wind speed measurements.Results show the use of six ventilation modules positioned below the window-sill, forming "a ventilated window-sill" is the best solution in terms of natural ventilation.
机译:风洞测试是确定自然通风对建筑物影响的可靠工具。本文介绍了风洞测试的结果,以评估通风模块对立面系统的影响。修改了模块的位置,导致外观不同。使用模型进行测试,改变立面配置中通风模块的位置。测试的案例是位于窗台下方(通风窗台)的六个通风模块,以及位于立面上方和下方的三个通风模块。提出的立面系统是可移动且可互换的,因此可以使用相同的基本模型来测试通风的可能性。在模型的内部和外部对不同的立面配置进行风速测量,以评估与自然通风相关的最佳性能。测量风速时考虑了单面通风和交叉通风。结果表明,在窗台下方使用了六个通风模块,形成“通风窗台”是自然通风方面的最佳解决方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号