首页> 外文OA文献 >Retinoscopy/autorefraction : which is the best starting point for a noncycloplegic refraction?
【2h】

Retinoscopy/autorefraction : which is the best starting point for a noncycloplegic refraction?

机译:检影/自动验光:非屈光性验光的最佳起点是什么?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A) and retinoscopy with subjective refraction. Methods: Measurements of autorefraction obtained with the ARK700A and retinoscopy were performed on 192 right eyes from 192 healthy young adults and compared with subjective refraction. These measurements were performed without cycloplegia. The age range was 18-34 years, with a mean value of 21.6 years and a standard deviation (SD) of 2.66 years. Results: A comparison of the autorefractor and subjective refraction results shows that; (1) for the mean spherical equivalent (M) the autorefractor yields more negative values (–0.44 ± 0.54 D, p = 0.000); (2) for the Jackson cross-cylinder at axis 0º (J0), the autorefractor yields more positive values than the subjective ones (–0.05 ± 0.13 D, p = 0.000); (3) and for the Jackson cross-cylinder at axis 45º (J45), the autorefractor results are more negative (–0.02 ± 0.09 D, p = 0.019). The differences found for each component M, J0 e J45 are statistically significant.By comparing retinoscopy with the subjective exam, there are no statistically significant differences found for the M component, (–0.02 ± 0.33 D, p = 0.304). For the J0 and J45 components, the differences are statistically significant (–0.07 ± 0.10 D, p = 0.000;–0.01 ± 0.08 D, p = 0.008). Conclusions: the present results confirm that when performed by an experienced clinician, retinoscopy is more accurate than automatic refraction giving a better starting point to non-cycloplegic refraction.
机译:目的:本研究的目的是评估自动验光仪(Nidek ARK 700A)与主观验光检影仪之间的一致性。方法:对来自192名健康年轻人的192眼右眼进行ARK700A自动验光和检影验光,并将其与主观验光进行比较。这些测量是在没有麻痹的情况下进行的。年龄范围为18-34岁,平均值为21.6岁,标准差(SD)为2.66岁。结果:自动验光仪和主观验光结果的比较表明: (1)对于平均球当量(M),自折射器产生更多的负值(–0.44±0.54 D,p = 0.000); (2)对于轴0º(J0)的杰克逊交叉圆柱,自折射器产生的正值比主观折射器的正值(–0.05±0.13 D,p = 0.000); (3)对于轴45º(J45)的杰克逊交叉圆柱,自动折射仪的结果更负(–0.02±0.09 D,p = 0.019)。每个成分M,J0和J45的差异具有统计学意义。通过将检影法与主观检查相比较,M成分之间无统计学意义的差异(–0.02±0.33 D,p = 0.304)。对于J0和J45组件,差异具有统计学意义(–0.07±0.10 D,p = 0.000; –0.01±0.08 D,p​​ = 0.008)。结论:目前的结果证实,由经验丰富的临床医生进行检查时,检影比自动验光更准确,为非屈光性验光提供了更好的起点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号