首页> 外文OA文献 >Pencil it in: pencil drawn electrochemical sensing platforms
【2h】

Pencil it in: pencil drawn electrochemical sensing platforms

机译:用铅笔写字:用铅笔绘制的电化学感应平台

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Inspired by recent reports concerning the utilisation of hand drawn pencil macroelectrodes (PDEs), we report the fabrication, characterisation (physicochemical and electrochemical) and implementation (electrochemical sensing) of various PDEs drawn upon a flexible polyester substrate. Electrochemical characterisation reveals that there are no quantifiable electrochemical responses upon utilising these PDEs with an electroactive analyte that requires an electrochemical oxidation step first, therefore the PDEs have been examined towards the electroactive redox probes hexaammineruthenium(III) chloride, potassium ferricyanide and ammonium iron(II) sulfate. For the first time, characterisation of the number of drawn pencil layers and the grade of pencil are examined; these parameters are commonly overlooked when utilising PDEs. It is demonstrated that a PDE drawn ten times with a 6B pencil presented the most advantageous electrochemical platform, in terms of electrochemical reversibility and peak height/analytical signal. In consideration of the aforementioned limitation, analytes requiring an electrochemical reduction as the first process were solely analysed. We demonstrate the beneficial electroanalytical capabilities of these PDEs towards p-benzoquinone and the simultaneous detection of heavy metals, namely lead(II) and cadmium(II), all of which are explored for the first time utilising PDEs. Initially, the detection limits of this system were higher than desired for electroanalytical platforms, however upon implementation of the PDEs in a back-to-back configuration (in which two PDEs are placed back-to-back sharing a single connection to the potentiostat), the detection limits for lead(II) and cadmium(II) correspond to 10 μg L−1 and 98 μg L−1 respectively within model aqueous (0.1 M HCl) solutions.
机译:受有关使用手绘铅笔大电极(PDE)的最新报告的启发,我们报告了在柔性聚酯基材上绘制的各种PDE的制造,表征(物理化学和电化学)和实现(电化学传感)。电化学表征表明,将这些PDE与需要先进行电化学氧化步骤的电活性分析物一起使用时,没有可量化的电化学响应,因此已对PDEs进行了电活性氧化还原探针六氯化钌(III),铁氰化钾和铁铵铁(II)的检测。 )硫酸盐。首次检查了绘制铅笔层数和铅笔等级的特性;使用PDE时,通常会忽略这些参数。结果表明,就电化学可逆性和峰高/分析信号而言,用6B铅笔绘制10次的PDE表现出最有利的电化学平台。考虑到上述限制,仅分析了需要电化学还原作为第一过程的分析物。我们证明了这些PDE对对苯醌的有益电分析能力以及同时检测重金属,即铅(II)和镉(II),这是所有首次使用PDE进行探索的方法。最初,该系统的检出限高于电分析平台所需的检出限,但是在以背靠背配置实现PDE时(其中两个PDE背靠背放置,共享与恒电位仪的单个连接) ,在标准水溶液(0.1 M HCl)中,铅(II)和镉(II)的检出限分别对应于10μgL-1和98μgL-1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号