This study discusses the use of potential distribution analysis during the deposition of metal ions, at limiting current conditions and determines the optimum electrode thickness at which no hydrogen evolution occurs. The potential distribution studies were carried out on stainless-steel fibres of three different surface areas. The fibres were used as cathodic porous electrodes during the deposition of Ag(I) ions contained in 0.1 mol dm− 3 KNO3 and 0.6 mol dm− 3 NH4OH electrolyte. The comparison between the experimental and the theoretical potential distributions show good agreement at mean linear flow rates in the range of 0.24 and 0.94 cm s− 1.
机译:这项研究讨论了在极限电流条件下在金属离子沉积过程中电势分布分析的用途,并确定了不会产生氢的最佳电极厚度。在三种不同表面积的不锈钢纤维上进行了电位分布研究。在沉积0.1 mol dm-3 KNO3和0.6 mol dm-3 NH4OH电解质中所含的Ag(I)离子期间,纤维被用作阴极多孔电极。实验和理论电势分布之间的比较表明,在0.24和0.94 cm s-1的平均线性流量下,一致性很好。