首页> 外文OA文献 >Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry
【2h】

Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry

机译:使用FlowBlurring®多重雾化器电感耦合等离子体发射光谱法分析不同原料中​​生物柴油B100中的金属和磷

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R2) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg−1. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g−1 for Mg (279.553 nm) and 531.1 ng g−1 for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g−1 for Ba (455.403 nm) and 2913.9 ng g−1 for Pb (220.353 nm). Recovery values ranged between 95% and 106%.
机译:一种简单快速的方法,使用两喷嘴FlowBlurring®多雾化器原型,通过电感耦合等离子体发射光谱(ICP OES)测定生物柴油样品中的Na,K,Ca,Mg,P和20种重金属的含量建议使用在线内标校准。生物柴油样品是通过碱催化剂酯交换反应从不同的原料(例如向日葵,玉米,大豆和葡萄籽油)生产的。无需任何样品预处理即可进行分析。通过多个雾化器喷嘴之一引入标准品和样品,而通过第二个喷嘴引入含钇作为内标物的水溶液。因此,光谱干扰得到了补偿,并防止了ICP焊炬上积碳的形成。对于所研究的分析物,测定系数(R2)大于0.99,范围为0.21–14.75 mg kg-1。短期和长期精度估计为相对标准偏差。这些是可接受的,它们的值低于10%。 Ca,K,Mg,Na和P等主要成分的LOQ在Mg(279.553 nm)的4.9 ng g-1和Na(588.995 nm)的531.1 ng g-1之间。其他20种次要成分,它们在Ba(455.403 nm)的1.1 ng g-1和Pb(220.353 nm)的2913.9 ng g-1之间。回收率介于95%和106%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号