A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED (λmax 500 nm) to discharge the detector LED (λmax 621 nm) from 5 V (logic 1) to 1.7 V (logic 0) to give digital output directly without using an A/D converter. \udEmploying a post-column reagent method, a Nucleosil 100-7 (functionalised with iminodiacetic acid (IDA) groups) column was used to separate a mixture of transition metal complexes, manganese (II) and cobalt (II) in PAR. All optical measurements were taken by using both the in built HPLC variable wavelength detector and the proposed paired-emitter-detector-diode (PEDD) optical detector configured in-line for data comparison. The concentration range investigated using the PEDD was found to give a linear response to the Mn (II) and Co (II) PAR complexes. The effects of flow rate and emitter LED light source intensity were investigated. Under optimised conditions the PEDD detector offered a linear range of 0.9-100 µM and LOD of 0.09 µM for Mn-PAR complex. A linear range of 0.2-100 µM and LOD of 0.09 µM for Co-PAR complex was achieved. \ud
机译:一种新颖的基于低功耗,低成本,高灵敏度,小型化的发光二极管(LED)的流量检测器已被用作光学检测器,用于检测高效液相色谱(HPLC)中的样品成分。该比色检测器使用两个LED,一个LED在正常模式下作为光源运行,而另一个反向偏置以用作光检测器。无需直接测量光电流,而是使用简单的计时器电路来测量发射器LED(λmax500 nm)产生的光电流从5 V(逻辑1)到1.7放电检测器LED(λmax621 nm)所需的时间。 V(逻辑0)直接提供数字输出,而无需使用A / D转换器。使用柱后试剂法,Nucleosil 100-7(用亚氨基二乙酸(IDA)基团官能化)色谱柱用于分离过渡金属配合物,锰(II)和钴(II)的混合物。通过使用内置的HPLC可变波长检测器和建议的成对发射极-检测器-二极管(PEDD)光学检测器进行在线配置,以进行数据比较,从而进行所有光学测量。发现使用PEDD研究的浓度范围对Mn(II)和Co(II)PAR配合物具有线性响应。研究了流速和发射器LED光源强度的影响。在最佳条件下,PEDD检测器的Mn-PAR配合物线性范围为0.9-100 µM,LOD为0.09 µM。 Co-PAR配合物的线性范围为0.2-100 µM,LOD为0.09 µM。 \ ud

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号