[ABSTRACT] The absorption spectra of CO_2, CO, and N_2O in the near infrared region were measured with a high-resolution Fourier transform spectrometer at room temperature to examine the uncertainties of the line parameters of the spectroscopic database. The line strengths and half-widths of these molecules were determined by a nonlinear least squares technique. We compared our results with the values compiled in the HITRAN databases. Large differences between the measured line strengths and the compiled ones in the HITRAN databases were found for the weak bands of each molecule. Air-broadened half-widths of CO_2, CO, and N_2O, which were calculated with measured N_2- and O_2-broadened half-widths, were close to the values of the HITRAN96 database. Self-broadened half-widths of CO_2 and N_2O agreed with the HITRAN96 values; while self-broadened half-widths of CO were different from the HITRAN96 values.
机译:[摘要]使用高分辨率傅里叶变换光谱仪在室温下测量近红外区域中CO_2,CO和N_2O的吸收光谱,以检查光谱数据库的线参数的不确定性。这些分子的线强度和半峰宽度通过非线性最小二乘法确定。我们将结果与HITRAN数据库中汇编的值进行了比较。对于每个分子的弱谱带,在HITRAN数据库中测得的谱线强度与汇编谱线强度之间存在较大差异。通过测量的N_2和O_2扩展的半宽计算出的CO_2,CO和N_2O的空气扩展的半宽与HITRAN96数据库的值接近。 CO_2和N_2O的自展宽半宽与HITRAN96值一致;而CO的自展宽半宽与HITRAN96值不同。